Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch


Lapić, Ivana; Rade, Anamarija; Kraljević, Anđela; Miloš, Marija; Coen Herak, Desiree; Daskijević, Lucija; Cerovac, Paula; Rogić, Dunja
Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch // Clinical chemistry and laboratory medicine (2023) doi:10.1515/cclm-2023-0033 (stručni, online first)


CROSBI ID: 1260244 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch

Autori
Lapić, Ivana ; Rade, Anamarija ; Kraljević, Anđela ; Miloš, Marija ; Coen Herak, Desiree ; Daskijević, Lucija ; Cerovac, Paula ; Rogić, Dunja

Vrsta, podvrsta
Radovi u časopisima, stručni

Izvornik
Clinical chemistry and laboratory medicine (2023)

Status rada
Online first

Ključne riječi
automation ; erythrocyte sedimentation rate ; validation study ; Westergren method

Sažetak
Objectives: Analytical validation of automated erythrocyte sedimentation rate (ESR) analyzers is necessary prior to their implementation into routine practice. Our aim was to perform the analytical validation of the modified Westergren method applied on the CUBE 30 touch analyzer (Diesse, Siena, Italy). Methods: Validation included determination of within-run and between-run precision following the Clinical and Laboratory Standards Institute EP15- A3 protocol, comparison with the reference Westergren method, sample stability assessment at both room temperature and 4 °C, after 4, 8 and 24- h storage, and checking the extent of hemolysis and lipemia interference. Results: Coefficients of variation (CVs) for within-run precision were 5.2% for the normal and 2.6% for the abnormal range, while between-run CVs were 9.4 and 2.2%, respectively. Comparison with the Westergren method (n=191) yielded Spearman's correlation coefficient of 0.93, no constant nor proportional difference [y=0.4 (95% CI: -1.7-1.0) + 1.06 (95% CI: 1.00-1.14)x] and a non-significant mean absolute bias of -2.6 mm (95% CI: -5.3-0.2). Lower comparability was evidenced with increasing ESR values, with both constant and proportional differences for ESR values between 40 and 80 mm, and above 80 mm. Sample stability was not compromised up to 8-h storage both at room temperature (p=0.054) and 4 °C (p=0.421). Hemolysis did not affect ESR measurement up to 1.0 g/L of free hemoglobin (p=0.089), while lipemia index above 5.0 g/L affects the ESR result (p=0.004). Conclusions: This study proved that CUBE 30 touch provides reliable ESR measurement and satisfactory comparability with the reference Westergren methods, with minor variation related to methodological differences.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
Opća bolnica Varaždin,
Klinički bolnički centar Zagreb

Profili:

Avatar Url Dunja Rogić (autor)

Avatar Url Desiree Coen Herak (autor)

Avatar Url Ivana Lapić (autor)

Avatar Url Marija Miloš (autor)

Poveznice na cjeloviti tekst rada:

doi www.degruyter.com

Citiraj ovu publikaciju:

Lapić, Ivana; Rade, Anamarija; Kraljević, Anđela; Miloš, Marija; Coen Herak, Desiree; Daskijević, Lucija; Cerovac, Paula; Rogić, Dunja
Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch // Clinical chemistry and laboratory medicine (2023) doi:10.1515/cclm-2023-0033 (stručni, online first)
Lapić, I., Rade, A., Kraljević, A., Miloš, M., Coen Herak, D., Daskijević, L., Cerovac, P. & Rogić, D. (2023) Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch. Prihvaćen za objavljivanje u Clinical chemistry and laboratory medicine. [Preprint] doi:10.1515/cclm-2023-0033.
@unknown{unknown, author = {Lapi\'{c}, Ivana and Rade, Anamarija and Kraljevi\'{c}, An\djela and Milo\v{s}, Marija and Coen Herak, Desiree and Daskijevi\'{c}, Lucija and Cerovac, Paula and Rogi\'{c}, Dunja}, year = {2023}, DOI = {10.1515/cclm-2023-0033}, keywords = {automation, erythrocyte sedimentation rate, validation study, Westergren method}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/cclm-2023-0033}, title = {Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch}, keyword = {automation, erythrocyte sedimentation rate, validation study, Westergren method} }
@unknown{unknown, author = {Lapi\'{c}, Ivana and Rade, Anamarija and Kraljevi\'{c}, An\djela and Milo\v{s}, Marija and Coen Herak, Desiree and Daskijevi\'{c}, Lucija and Cerovac, Paula and Rogi\'{c}, Dunja}, year = {2023}, DOI = {10.1515/cclm-2023-0033}, keywords = {automation, erythrocyte sedimentation rate, validation study, Westergren method}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/cclm-2023-0033}, title = {Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch}, keyword = {automation, erythrocyte sedimentation rate, validation study, Westergren method} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font