Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1257076

Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks


Knez, Nora; Mitar, Luka; Lojo, Nermin; Halužan, Damir; Perkov, Dražen
Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks // Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 144 (2022), Suppl 7
Zagreb, Hrvatska, 2022. str. 23-23 doi:10.26800/LV-144-supl7-23 (poster, podatak o recenziji nije dostupan, sažetak, stručni)


CROSBI ID: 1257076 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks

Autori
Knez, Nora ; Mitar, Luka ; Lojo, Nermin ; Halužan, Damir ; Perkov, Dražen

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 144 (2022), Suppl 7 / - , 2022, 23-23

Skup
22nd ZIMS Zagreb International Medical Summit for Medical Students and Young Doctors

Mjesto i datum
Zagreb, Hrvatska, 15.12.2022. - 18.12.2022

Vrsta sudjelovanja
Poster

Vrsta recenzije
Podatak o recenziji nije dostupan

Ključne riječi
endoleak ; endovascular aneurysm repair ; surveillance

Sažetak
Background: Endovascular aneurysm repair (EVAR) has become a well-established approach in the elective treatment of abdominal aortic aneurysms (AAA). It represents a treatment of choice for high-risk patients ineligible for open surgery due to the increased risk of perioperative morbidity and mortality. However, it requires lifelong surveillance with CT aortography (CTA) or contrast- enhanced ultrasound due to more long-term complications compared to open surgery. Endoleak is the most common graft- related complication with type II endoleak being the most common type. Type I and III endoleaks (T1E, T3E) are the most dangerous type of endoleaks, both leading to pressurization of the aneurysm sac and rupture. Case presentation: We report the case of a 72-year-old male patient with various types of endoleaks after EVAR. In 2015 ASA IV patient with known asymptomatic infrarenal 6.6x6cm AAA underwent elective EVAR with main device and bilateral iliac limbs (Medtronic, Endurant II). His past medical history revealed myocardial infarction, ischemic cardiomyopathy, hypertension, pancreatitis, and cholecystectomy. He was on regular stent-graft surveillance. Until 2021 he had been free of any EVAR-related complications when he presented to the emergency department with cramping abdominal pain. CTA demonstrated the presence of T1aE and T1bE. ChEVAR with Aortic Extension 32mm (Medtronic, Endurant II) and BeGraft Peripheral 5x59mm for T1Ea, stent grafting with two additional main device extensions, 28x28mm and 13x13mm, for T1Eb followed by ballooning, was successfully performed. Follow-up CTA in 2022 revealed the presence of a T3E that was immediately managed with an additional 16x10x199 mm endograft extension and by repeat ballooning at areas of component overlap. Conclusions: Endoleak is an important complication for EVAR which is often asymptomatic hence regular follow-up is needed and immediate management is crucial to prevent future aneurysm rupture. Nevertheless, this case demonstrates the importance of lifelong attentive surveillance to promptly diagnose and treat complications.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb

Profili:

Avatar Url Damir Halužan (autor)

Avatar Url Nora Knez (autor)

Avatar Url DRAŽEN PERKOV (autor)

Avatar Url Nermin Lojo (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi hrcak.srce.hr

Citiraj ovu publikaciju:

Knez, Nora; Mitar, Luka; Lojo, Nermin; Halužan, Damir; Perkov, Dražen
Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks // Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 144 (2022), Suppl 7
Zagreb, Hrvatska, 2022. str. 23-23 doi:10.26800/LV-144-supl7-23 (poster, podatak o recenziji nije dostupan, sažetak, stručni)
Knez, N., Mitar, L., Lojo, N., Halužan, D. & Perkov, D. (2022) Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks. U: Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 144 (2022), Suppl 7 doi:10.26800/LV-144-supl7-23.
@article{article, author = {Knez, Nora and Mitar, Luka and Lojo, Nermin and Halu\v{z}an, Damir and Perkov, Dra\v{z}en}, year = {2022}, pages = {23-23}, DOI = {10.26800/LV-144-supl7-23}, keywords = {endoleak, endovascular aneurysm repair, surveillance}, doi = {10.26800/LV-144-supl7-23}, title = {Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks}, keyword = {endoleak, endovascular aneurysm repair, surveillance}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Knez, Nora and Mitar, Luka and Lojo, Nermin and Halu\v{z}an, Damir and Perkov, Dra\v{z}en}, year = {2022}, pages = {23-23}, DOI = {10.26800/LV-144-supl7-23}, keywords = {endoleak, endovascular aneurysm repair, surveillance}, doi = {10.26800/LV-144-supl7-23}, title = {Never underestimate the importance of surveillance – a case report of a patient with post-EVAR endoleaks}, keyword = {endoleak, endovascular aneurysm repair, surveillance}, publisherplace = {Zagreb, Hrvatska} }

Časopis indeksira:


  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font