Pregled bibliografske jedinice broj: 1250077
A randomized crossover study comparing membrane and centrifugal therapeutic plasma exchange procedures
A randomized crossover study comparing membrane and centrifugal therapeutic plasma exchange procedures // Transfusion, 56 (2016), 12; 3065-3072 doi:10.1111/trf.13850 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1250077 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
A randomized crossover study comparing membrane and centrifugal
therapeutic plasma exchange procedures
Autori
Kes, Petar ; Janssens, Michiel Etienne ; Bašić‐Jukić, Nikolina ; Kljak, Milića
Izvornik
Transfusion (0041-1132) 56
(2016), 12;
3065-3072
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
plasma exchange
Sažetak
Background: Therapeutic plasma exchange (TPE) can be performed either on a membrane-based system (mTPE) or on a device that separates blood components by centrifugation (cTPE). The number of studies in this field is limited. This randomized study is the first that offers data on the membrane-based Diapact device (B. Braun Medical, Inc.) for TPE procedures and compares it to the centrifuge- based Spectra Optia (Terumo BCT, Inc.). Study design and methods: Twenty-seven patients were enrolled in this randomized prospective head-to-head study comparing the mTPE and cTPE systems. Procedures on both devices were standardized and the plasma removal efficiency (PRE) ; total procedure time (including setup and priming time) ; and removal efficiencies of blood cells, immunoglobulin (Ig)G, and fibrinogen for all procedures were analyzed. Results: While both systems removed similar amounts of plasma, it took the cTPE device a mean of 101.5 ± 24.6 minutes to finalize a procedure that was one-third less than procedures on the mTPE device (157 ± 26.2 min ; p < 0.0001), due to a difference in PRE between the Spectra Optia (83.0% ± 4.9%) and the Diapact (53.2% ± 6.6% ; p < 0.0001). The difference in removal efficiencies of IgG and blood cells were not significantly different but the Spectra Optia was more efficient in removing the larger fibrinogen protein than the Diapact (72.3% ± 8.5% vs. 62.9% ± 16.1%, respectively ; p < 0.02). Conclusion: This study shows that, although both systems perform adequate and safe TPE procedures, those on the Spectra Optia in comparison to the Diapact are more efficient in terms of plasma removal and significantly shorter.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb
Profili:
Petar Kes
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE