Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1249532

Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media


Obajdin, Nevena; Smilović Radojčić, Đeni; Rajlić, David; Švabić Kolacio, Manda; Jurković, Slaven
Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media // Nuclear technology & radiation protection, 37 (2022), 2; 138-144 doi:10.2298/NTRP2202138O (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1249532 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media

Autori
Obajdin, Nevena ; Smilović Radojčić, Đeni ; Rajlić, David ; Švabić Kolacio, Manda ; Jurković, Slaven

Izvornik
Nuclear technology & radiation protection (1451-3994) 37 (2022), 2; 138-144

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
pre-treatment ab orbed dose verification, tolerance criteria, inhomogeneous media, calculation algorithm, patient safety

Sažetak
Advances of radiation delivery devices have increased the complexity of the radiation oncology treatments. Herewith, outcome of the treatment, as well as patient safety, strongly depend on the consistency of absorbed dose delivery. Both can be ensured by comprehensive system of verification of calculated absorbed dose distributions. Standard method is evaluation of calculated absorbed dose distribution according to gamma method, using a 2- D detector and a homogeneous phantom, to obtain measured dose distribution. Purpose of this research was to investigate the influence of tolerance criteria on gamma passing rate. Additionally, the agreement in heterogeneous phantom was analysed. Absorbed dose calculations were performed using systems Monaco and XiO. Detector with 1020 ionization chambers in homogeneous phantom and semi-anthropomorphic phantom was used for measurements. Absorbed dose distributions of around 3500 patients were analysed using gamma method. In homogeneous phantom, average gamma passing rates were within tolerance for 3 %/2 mm. For measurements in heterogeneous media, the highest average gamma passing rate was obtained for small volumes of medium treatment complexity (γ ̅= 93.84 %), while large volumes of treatment with low complexity yielded the lowest gamma passing rates (γ ̅= 83.22 %).

Izvorni jezik
Engleski



POVEZANOST RADA


Poveznice na cjeloviti tekst rada:

doi ntrp.vinca.rs

Citiraj ovu publikaciju:

Obajdin, Nevena; Smilović Radojčić, Đeni; Rajlić, David; Švabić Kolacio, Manda; Jurković, Slaven
Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media // Nuclear technology & radiation protection, 37 (2022), 2; 138-144 doi:10.2298/NTRP2202138O (međunarodna recenzija, članak, znanstveni)
Obajdin, N., Smilović Radojčić, Đ., Rajlić, D., Švabić Kolacio, M. & Jurković, S. (2022) Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media. Nuclear technology & radiation protection, 37 (2), 138-144 doi:10.2298/NTRP2202138O.
@article{article, author = {Obajdin, Nevena and Smilovi\'{c} Radoj\v{c}i\'{c}, \DJeni and Rajli\'{c}, David and \v{S}vabi\'{c} Kolacio, Manda and Jurkovi\'{c}, Slaven}, year = {2022}, pages = {138-144}, DOI = {10.2298/NTRP2202138O}, keywords = {pre-treatment ab orbed dose verification, tolerance criteria, inhomogeneous media, calculation algorithm, patient safety}, journal = {Nuclear technology and radiation protection}, doi = {10.2298/NTRP2202138O}, volume = {37}, number = {2}, issn = {1451-3994}, title = {Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media}, keyword = {pre-treatment ab orbed dose verification, tolerance criteria, inhomogeneous media, calculation algorithm, patient safety} }
@article{article, author = {Obajdin, Nevena and Smilovi\'{c} Radoj\v{c}i\'{c}, \DJeni and Rajli\'{c}, David and \v{S}vabi\'{c} Kolacio, Manda and Jurkovi\'{c}, Slaven}, year = {2022}, pages = {138-144}, DOI = {10.2298/NTRP2202138O}, keywords = {pre-treatment ab orbed dose verification, tolerance criteria, inhomogeneous media, calculation algorithm, patient safety}, journal = {Nuclear technology and radiation protection}, doi = {10.2298/NTRP2202138O}, volume = {37}, number = {2}, issn = {1451-3994}, title = {Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media}, keyword = {pre-treatment ab orbed dose verification, tolerance criteria, inhomogeneous media, calculation algorithm, patient safety} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font