Rebound Tonometry over Soft Contact Lenses


Krolo, Iva; Mihaljevic, Boze; Kasumovic, Aida; Ravlic, Maja; Herman, Jelena
Rebound Tonometry over Soft Contact Lenses // Acta Informatica Medica, 28 (2020), 3; 185-189 doi:10.5455/aim.2020.28.185-189 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1247358 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Rebound Tonometry over Soft Contact Lenses

Autori
Krolo, Iva ; Mihaljevic, Boze ; Kasumovic, Aida ; Ravlic, Maja ; Herman, Jelena

Izvornik
Acta Informatica Medica (0353-8109) 28 (2020), 3; 185-189

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Contact Lens, Rebound Tonometry, Icare, Hydrogel, Silicone Hydrogel.

Sažetak
Goldmann applanation tonometry (GAT) is named as a gold standard for intraocular pressure (IOP) measurement. Aim: To assess the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over hydrogel and silicone hydrogel contact lenses (CLs) of different powers. Methods: This study included 117 eyes of 61 patients (12 male, 49 female), all habitual wearers of hydrogel and silicone hydrogel CLs, and none previously diagnosed with glaucoma, ocular hypertension or anterior surface disease. Five IOP measurements were taken over each eye using a rebound tonometer (Icare): with soft CLs in situ and then repeated without CLs. Lens power ranged from -9.50 to +10.00 spherical diopters and to a maximum of -0.75 cylinder diopters. Results: A significant positive correlation was found between IOP measurements with and without CLs. The difference between IOP measurements with (mean 20.74±5.19 mmHg) and without (mean 18.79±4.36 mmHg) CLs was found to be 1.95 mmHg (P <0.01). Statistical analysis was performed using the paired t-test and a correlation coefficient was calculated (r = 0.59 ; P <0.001). We have observed that increase in central corneal thickness (CCT) correlates positively with increase of measurement error of rebound tonometry (r = 0.43 ; P <0.001). C

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Profili:

Avatar Url Iva Krolo (autor)

Poveznice na cjeloviti tekst rada:

doi www.ncbi.nlm.nih.gov

Citiraj ovu publikaciju:

Krolo, Iva; Mihaljevic, Boze; Kasumovic, Aida; Ravlic, Maja; Herman, Jelena
Rebound Tonometry over Soft Contact Lenses // Acta Informatica Medica, 28 (2020), 3; 185-189 doi:10.5455/aim.2020.28.185-189 (međunarodna recenzija, članak, znanstveni)
Krolo, I., Mihaljevic, B., Kasumovic, A., Ravlic, M. & Herman, J. (2020) Rebound Tonometry over Soft Contact Lenses. Acta Informatica Medica, 28 (3), 185-189 doi:10.5455/aim.2020.28.185-189.
@article{article, author = {Krolo, Iva and Mihaljevic, Boze and Kasumovic, Aida and Ravlic, Maja and Herman, Jelena}, year = {2020}, pages = {185-189}, DOI = {10.5455/aim.2020.28.185-189}, keywords = {Contact Lens, Rebound Tonometry, Icare, Hydrogel, Silicone Hydrogel.}, journal = {Acta Informatica Medica}, doi = {10.5455/aim.2020.28.185-189}, volume = {28}, number = {3}, issn = {0353-8109}, title = {Rebound Tonometry over Soft Contact Lenses}, keyword = {Contact Lens, Rebound Tonometry, Icare, Hydrogel, Silicone Hydrogel.} }
@article{article, author = {Krolo, Iva and Mihaljevic, Boze and Kasumovic, Aida and Ravlic, Maja and Herman, Jelena}, year = {2020}, pages = {185-189}, DOI = {10.5455/aim.2020.28.185-189}, keywords = {Contact Lens, Rebound Tonometry, Icare, Hydrogel, Silicone Hydrogel.}, journal = {Acta Informatica Medica}, doi = {10.5455/aim.2020.28.185-189}, volume = {28}, number = {3}, issn = {0353-8109}, title = {Rebound Tonometry over Soft Contact Lenses}, keyword = {Contact Lens, Rebound Tonometry, Icare, Hydrogel, Silicone Hydrogel.} }

Časopis indeksira:


  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font