Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1246944

Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach


Duvančić, Tea; Škokić, Siniša; Erjavec, Igor; Plečko, Mihovil; Bohaček, Ivan; Gajović, Srećko; Delimar, Domagoj
Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach // Croatian medical journal, 63 (2022), 6; 515-524 doi:10.3325/cmj.2022.63.515 (recenziran, članak, znanstveni)


CROSBI ID: 1246944 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach
(Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach)

Autori
Duvančić, Tea ; Škokić, Siniša ; Erjavec, Igor ; Plečko, Mihovil ; Bohaček, Ivan ; Gajović, Srećko ; Delimar, Domagoj

Izvornik
Croatian medical journal (0353-9504) 63 (2022), 6; 515-524

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
cancellous bone ; humans ; magnetic resonance imaging ; osteoarthritis, hip / diagnostic imaging ; osteoarthritis, hip / surgery ; protons ; x-ray microtomography / methods

Sažetak
Aim: To test the agreement between a newly developed micro-magnetic resonance imaging (MRI) analysis of the subchondral bone and the micro-computed tomography (CT) approach. ----- Methods: Samples obtained from 10 patients with osteoarthritis undergoing total hip arthroplasty were scanned with a 7.0 T micro-MRI. Proton density- weighted images and proton density-weighted images with fat suppression were obtained. The results were validated with a micro-CT device. Micro-MRI and micro-CT scans of the same sample were aligned, and regions of interest were delineated on equal areas of the sample. Bone volume fraction was calculated by using in-house plugins. The agreement between the methods was tested with Bland- Altman analysis. ----- Results: The agreement between the methods was good, with average difference of 2.167%. The differences between the methods were not significant (P=0.272, t test). ----- Conclusion: The novel micro-MRI approach could be used for subchondral bone analysis. With further optimization for clinical MRI machines, the approach can be also used in the diagnostics of hip osteoarthritis.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
IP-2018-01-3688 - Karakterizacija hrskavice acetabuluma i femura u odraslih bolesnika s razvojnim poremećajem kuka (HIPoCART) (Delimar, Domagoj, HRZZ - 2018-01) ( CroRIS)

Ustanove:
Medicinski fakultet, Zagreb

Poveznice na cjeloviti tekst rada:

doi www.cmj.hr

Citiraj ovu publikaciju:

Duvančić, Tea; Škokić, Siniša; Erjavec, Igor; Plečko, Mihovil; Bohaček, Ivan; Gajović, Srećko; Delimar, Domagoj
Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach // Croatian medical journal, 63 (2022), 6; 515-524 doi:10.3325/cmj.2022.63.515 (recenziran, članak, znanstveni)
Duvančić, T., Škokić, S., Erjavec, I., Plečko, M., Bohaček, I., Gajović, S. & Delimar, D. (2022) Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach. Croatian medical journal, 63 (6), 515-524 doi:10.3325/cmj.2022.63.515.
@article{article, author = {Duvan\v{c}i\'{c}, Tea and \v{S}koki\'{c}, Sini\v{s}a and Erjavec, Igor and Ple\v{c}ko, Mihovil and Boha\v{c}ek, Ivan and Gajovi\'{c}, Sre\'{c}ko and Delimar, Domagoj}, year = {2022}, pages = {515-524}, DOI = {10.3325/cmj.2022.63.515}, keywords = {cancellous bone, humans, magnetic resonance imaging, osteoarthritis, hip / diagnostic imaging, osteoarthritis, hip / surgery, protons, x-ray microtomography / methods}, journal = {Croatian medical journal}, doi = {10.3325/cmj.2022.63.515}, volume = {63}, number = {6}, issn = {0353-9504}, title = {Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach}, keyword = {cancellous bone, humans, magnetic resonance imaging, osteoarthritis, hip / diagnostic imaging, osteoarthritis, hip / surgery, protons, x-ray microtomography / methods} }
@article{article, author = {Duvan\v{c}i\'{c}, Tea and \v{S}koki\'{c}, Sini\v{s}a and Erjavec, Igor and Ple\v{c}ko, Mihovil and Boha\v{c}ek, Ivan and Gajovi\'{c}, Sre\'{c}ko and Delimar, Domagoj}, year = {2022}, pages = {515-524}, DOI = {10.3325/cmj.2022.63.515}, keywords = {cancellous bone, humans, magnetic resonance imaging, osteoarthritis, hip / diagnostic imaging, osteoarthritis, hip / surgery, protons, x-ray microtomography / methods}, journal = {Croatian medical journal}, doi = {10.3325/cmj.2022.63.515}, volume = {63}, number = {6}, issn = {0353-9504}, title = {Novel micro-MRI approach for subchondral trabecular bone analysis in patients with hip osteoarthritis is comparable to micro-CT approach}, keyword = {cancellous bone, humans, magnetic resonance imaging, osteoarthritis, hip / diagnostic imaging, osteoarthritis, hip / surgery, protons, x-ray microtomography / methods} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font