Pregled bibliografske jedinice broj: 1237423
Temporal changes in pulmonary gas exchange efficiency when breath-hold diving below residual volume
Temporal changes in pulmonary gas exchange efficiency when breath-hold diving below residual volume // Experimental physiology, 106 (2021), 4; 1120-1133 doi:10.1113/EP089176 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1237423 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Temporal changes in pulmonary gas exchange
efficiency when breath-hold diving below residual
volume
Autori
Patrician, Alexander ; Spajić, Boris ; Gasho, Christopher ; Caldwell, Hannah G. ; Dawkins, Tony ; Stembridge, Michael ; Lovering, Andrew T. ; Coombs, Geoff B. ; Howe, Connor A. ; Barak, Otto ; Drviš, Ivan ; Dujić, Željko ; Ainslie, Philip N.
Izvornik
Experimental physiology (0958-0670) 106
(2021), 4;
1120-1133
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
breath-hold ; diving ; immersion ; lung compression ; pulmonary gas exchange ; residual volume ; spirometry
Sažetak
New Findings What is the central question of this study? How does deep breath-hold diving impact cardiopulmonary function, both acutely and over the subsequent 2.5 hours post-dive? What is the main finding and its importance? Breath-hold diving, to depths below residual volume, is associated with acute impairments in pulmonary gas exchange, which typically resolve within 2.5 hours. These data provide new insight into the behaviour of the lungs and pulmonary vasculature following deep diving. Breath-hold diving involves highly integrative and extreme physiological responses to both exercise and asphyxia during progressive elevations in hydrostatic pressure. Over two diving training camps (Study 1 and 2), 25 breath-hold divers (recreational to world- champion) performed 66 dives to 57 +/- 20 m (range: 18-117 m). Using the deepest dive from each diver, temporal changes in cardiopulmonary function were assessed using non-invasive pulmonary gas exchange (indexed via the O-2 deficit), ultrasound B-line scores, lung compliance and pulmonary haemodynamics at baseline and following the dive. Hydrostatically induced lung compression was quantified in Study 2, using spirometry and lung volume measurement, enabling each dive to be categorized by its residual volume (RV)-equivalent depth. From both studies, pulmonary gas exchange inefficiency - defined as an increase in O-2 deficit - was related to the depth of the dive (r(2 )= 0.345 ; P < 0.001), with dives associated with lung squeeze symptoms exhibiting the greatest deficits. In Study 1, although B-lines doubled from baseline (P = 0.027), cardiac output and pulmonary artery systolic pressure were unchanged post-dive. In Study 2, dives with lung compression to <= RV had higher O-2 deficits at 9 min, compared to dives that did not exceed RV (24 +/- 25 vs. 5 +/- 8 mmHg ; P = 0.021). The physiological significance of a small increase in estimated lung compliance post-dive (via decreased and increased/unaltered airway resistance and reactance, respectively) remains equivocal. Following deep dives, the current study highlights an integrated link between hydrostatically induced lung compression and transient impairments in pulmonary gas exchange efficiency.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE