Evaluation of the statistical distributions of transient impedance of the horizontal grounding electrode subject to lightning strike
Evaluation of the statistical distributions of transient impedance of the horizontal grounding electrode subject to lightning strike // URSI GASS 2021
Rim, Italija, 2021. Mo-E01-AM2-1, 1 (predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 1235755 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Evaluation of the statistical distributions of transient impedance of the horizontal grounding electrode subject to lightning strike
Autori
Lallechere, Sebastien ; Sesnic, Silvestar ; Susnjara, Anna ; Poljak, Dragan ; El Khamlichi Drissi, Khalil
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Skup
URSI GASS 2021
Mjesto i datum
Rim, Italija, 28.08-04.09.2021
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
statistical distribution ; transient impedance ; grounding electrode
Sažetak
In the framework of the lightning protection systems (LPS), transient impedance is considered as a key parameter to determine the performance of a given system [1]. It is well documented that such complex systems require a careful analysis due to the severity and risk of under-estimating protection levels along with the volatility of the inputs range. On the one hand, different strategies have been successfully tested during the past years, mainly based on different assumptions and methods of solution, e.g. see use of a direct time domain solution for the transient impedance (ZT) [2]. On the other hand, the uncertainty quantification (UQ) is needed for the assessment of ZT statistics. Sesnic et al. [3] proposed an accurate assessment of LPS sensitivity analysis at sparing computing costs. Indeed, due to the inability to precisely measure certain input parameters (soil conductivity, for instance) or in relation with the stochastic nature of the phenomena (e.g. lighting pulse) [1], it is major concern to evaluate ZT distribution for a realistic computational cost. In this proposal, a perfectly conducting (PEC) grounding electrode is excited by a lightning strike with uncertain inputs as given in Tab. 1. This work lays emphasis on the use of three stochastic strategies, including classical Monte Carlo (MC) method, stochastic collocation technique (SCT), and stochastic reduced order method (SROM) [4]. Fig.1 shows the capability of SCT and SROM to reproduce ZT statistical distributions at early stage and/or during steady state, comparatively to MC. The final paper will give details of the theoretical background of the proposed stochastic methods and their validation through numerical test cases.