Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt


Marshall-Goebel, Karina; Terlević, Robert; Gerlach, Darius A.; Kuehn, Simone; Mulder, Edwin; Rittweger, Jörn
Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt // Journal of Applied Physiology, 123 (2017), 5; 1139-1144 doi:10.1152/japplphysiol.00256.2017 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1215896 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt

Autori
Marshall-Goebel, Karina ; Terlević, Robert ; Gerlach, Darius A. ; Kuehn, Simone ; Mulder, Edwin ; Rittweger, Jörn

Izvornik
Journal of Applied Physiology (8750-7587) 123 (2017), 5; 1139-1144

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
carbon dioxide ; cerebrospinal fluid ; intracranial pressure ; intracranial volumes ; microgravity.

Sažetak
The microgravity ocular syndrome (MOS) results in significant structural and functional ophthalmic changes during 6-mo spaceflight missions consistent with an increase in cerebrospinal fluid (CSF) pressure compared with the preflight upright position. A ground-based study was performed to assess two of the major hypothesized contributors to MOS, headward fluid shifting and increased ambient CO2, on intracranial and periorbital CSF. In addition, lower body negative pressure (LBNP) was assessed as a countermeasure to headward fluid shifting. Nine healthy male subjects participated in a crossover design study with five head-down tilt (HDT) conditions: -6, -12, and -18° HDT, -12° HDT with -20 mmHg LBNP, and -12° HDT with a 1% CO2 environment, each for 5 h total. A three-dimensional volumetric scan of the cranium and transverse slices of the orbita were collected with MRI, and intracranial CSF volume and optic nerve sheath diameter (ONSD) were measured after 4.5 h HDT. ONSD increased during -6° (P < 0.001), -12° (P < 0.001), and -18° HDT (P < 0.001) and intracranial CSF increased during -12° HDT (P = 0.01) compared with supine baseline. Notably, LBNP was able to reduce the increases in ONSD and intracranial CSF during HDT. The addition of 1% CO2 during HDT, however, had no further effect on ONSD, but rather ONSD increased from baseline in a similar magnitude to -12° HDT with ambient air (P = 0.001). These findings demonstrate the ability of LBNP, a technique that targets fluid distribution in the lower limbs, to directly influence CSF and may be a promising countermeasure to help reduce increases in CSF.NEW & NOTEWORTHY This is the first study to demonstrate the ability of lower body negative pressure to directly influence cerebrospinal fluid surrounding the optic nerve, indicating potential use as a countermeasure for increased cerebrospinal fluid on Earth or in space.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Marshall-Goebel, Karina; Terlević, Robert; Gerlach, Darius A.; Kuehn, Simone; Mulder, Edwin; Rittweger, Jörn
Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt // Journal of Applied Physiology, 123 (2017), 5; 1139-1144 doi:10.1152/japplphysiol.00256.2017 (međunarodna recenzija, članak, znanstveni)
Marshall-Goebel, K., Terlević, R., Gerlach, D., Kuehn, S., Mulder, E. & Rittweger, J. (2017) Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt. Journal of Applied Physiology, 123 (5), 1139-1144 doi:10.1152/japplphysiol.00256.2017.
@article{article, author = {Marshall-Goebel, Karina and Terlevi\'{c}, Robert and Gerlach, Darius A. and Kuehn, Simone and Mulder, Edwin and Rittweger, J\"{o}rn}, year = {2017}, pages = {1139-1144}, DOI = {10.1152/japplphysiol.00256.2017}, keywords = {carbon dioxide, cerebrospinal fluid, intracranial pressure, intracranial volumes, microgravity.}, journal = {Journal of Applied Physiology}, doi = {10.1152/japplphysiol.00256.2017}, volume = {123}, number = {5}, issn = {8750-7587}, title = {Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt}, keyword = {carbon dioxide, cerebrospinal fluid, intracranial pressure, intracranial volumes, microgravity.} }
@article{article, author = {Marshall-Goebel, Karina and Terlevi\'{c}, Robert and Gerlach, Darius A. and Kuehn, Simone and Mulder, Edwin and Rittweger, J\"{o}rn}, year = {2017}, pages = {1139-1144}, DOI = {10.1152/japplphysiol.00256.2017}, keywords = {carbon dioxide, cerebrospinal fluid, intracranial pressure, intracranial volumes, microgravity.}, journal = {Journal of Applied Physiology}, doi = {10.1152/japplphysiol.00256.2017}, volume = {123}, number = {5}, issn = {8750-7587}, title = {Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt}, keyword = {carbon dioxide, cerebrospinal fluid, intracranial pressure, intracranial volumes, microgravity.} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font