Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol


Dabin, Jérémie; Blidéanu, Valentin; Ciraj Bjelac, Olivera; Deleu, Marine; De Monte, Francesca; Feghali, Joëlle Ann; Gallagher, Aoife; Knežević, Željka; Maccia, Carlo; Malchair, Françoise et al.
Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol // Physica medica, 82 (2021), 279-294 doi:10.1016/j.ejmp.2021.02.016 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1206961 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol

Autori
Dabin, Jérémie ; Blidéanu, Valentin ; Ciraj Bjelac, Olivera ; Deleu, Marine ; De Monte, Francesca ; Feghali, Joëlle Ann ; Gallagher, Aoife ; Knežević, Željka ; Maccia, Carlo ; Malchair, Françoise ; Sans Merce, Marta ; Simantirakis, George

Izvornik
Physica medica (1120-1797) 82 (2021); 279-294

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Interventional cardiology ; Skin dose ; Skin dose mapping ; Quality control protocol

Sažetak
Online and offline software products can estimate the maximum skin dose (MSD) delivered to the patient during interventional cardiology procedures. The capabilities and accuracy of several skin dose mapping (SDM) software products were assessed on X-ray systems from the main manufacturers following a common protocol. Skin dose was measured on four X-ray systems following a protocol composed of nine fundamental irradiation set-ups and three set-ups simulating short, clinical procedures. Dosimeters/multimeters with semiconductor-based detectors, radiochromic films and thermoluminescent dosimeters were used. Results were compared with up to eight of 10 SDM products, depending on their compatibility. he MSD estimates generally agreed with the measurements within ± 40% for fundamental irradiation set-ups and simulated procedures. Only three SDM products provided estimates within ± 40% for all tested configurations on at least one compatible X-ray system. No SDM product provided estimates within ± 40% for all combinations of configurations and compatible systems. The accuracy of the MSD estimate for lateral irradiations was variable and could be poor (up to 66% underestimation). Most SDM products produced maps which qualitatively represented the dimensions, the shape and the relative position of the MSD region. Some products, however, missed the MSD region when situated at the intersection of multiple fields, which is of radiation protection concern. It is very challenging to establish a common protocol for quality control (QC) and acceptance testing because not all information necessary for accurate MSD calculation is available or standardised in the radiation dose structured reports (RDSRs).

Izvorni jezik
Engleski

Znanstvena područja
Interdisciplinarne prirodne znanosti, Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
EK-62287 - Validacija i procjena kožne doze zračenja u intervencijskoj kardiologiji (VERIDIC) (Knežević Medija, Željka, EK ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Željka Knežević Medija (autor)

Citiraj ovu publikaciju:

Dabin, Jérémie; Blidéanu, Valentin; Ciraj Bjelac, Olivera; Deleu, Marine; De Monte, Francesca; Feghali, Joëlle Ann; Gallagher, Aoife; Knežević, Željka; Maccia, Carlo; Malchair, Françoise et al.
Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol // Physica medica, 82 (2021), 279-294 doi:10.1016/j.ejmp.2021.02.016 (međunarodna recenzija, članak, znanstveni)
Dabin, J., Blidéanu, V., Ciraj Bjelac, O., Deleu, M., De Monte, F., Feghali, J., Gallagher, A., Knežević, Ž., Maccia, C. & Malchair, F. (2021) Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol. Physica medica, 82, 279-294 doi:10.1016/j.ejmp.2021.02.016.
@article{article, author = {Dabin, J\'{e}r\'{e}mie and Blid\'{e}anu, Valentin and Ciraj Bjelac, Olivera and Deleu, Marine and De Monte, Francesca and Feghali, Jo\"{e}lle Ann and Gallagher, Aoife and Kne\v{z}evi\'{c}, \v{Z}eljka and Maccia, Carlo and Malchair, Fran\c{c}oise and Sans Merce, Marta and Simantirakis, George}, year = {2021}, pages = {279-294}, DOI = {10.1016/j.ejmp.2021.02.016}, keywords = {Interventional cardiology, Skin dose, Skin dose mapping, Quality control protocol}, journal = {Physica medica}, doi = {10.1016/j.ejmp.2021.02.016}, volume = {82}, issn = {1120-1797}, title = {Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol}, keyword = {Interventional cardiology, Skin dose, Skin dose mapping, Quality control protocol} }
@article{article, author = {Dabin, J\'{e}r\'{e}mie and Blid\'{e}anu, Valentin and Ciraj Bjelac, Olivera and Deleu, Marine and De Monte, Francesca and Feghali, Jo\"{e}lle Ann and Gallagher, Aoife and Kne\v{z}evi\'{c}, \v{Z}eljka and Maccia, Carlo and Malchair, Fran\c{c}oise and Sans Merce, Marta and Simantirakis, George}, year = {2021}, pages = {279-294}, DOI = {10.1016/j.ejmp.2021.02.016}, keywords = {Interventional cardiology, Skin dose, Skin dose mapping, Quality control protocol}, journal = {Physica medica}, doi = {10.1016/j.ejmp.2021.02.016}, volume = {82}, issn = {1120-1797}, title = {Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol}, keyword = {Interventional cardiology, Skin dose, Skin dose mapping, Quality control protocol} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font