Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1206159

The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups


Kisić, Dominik; Horvat, Marko; Jambrošić, Kristian; Franček, Petar
The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups // Applied Sciences-Basel, 12 (2022), 14; 7202, 17 doi:10.3390/app12147202 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1206159 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups

Autori
Kisić, Dominik ; Horvat, Marko ; Jambrošić, Kristian ; Franček, Petar

Izvornik
Applied Sciences-Basel (2076-3417) 12 (2022), 14; 7202, 17

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
listening tests ; non-laboratory environment ; online/home test setup ; level calibration ; speech

Sažetak
The pandemic of COVID-19 and the resulting countermeasures have made it difficult or impossible to perform listening tests in controlled laboratory environments. This paper examines the possibility of using speech for level calibration of sound reproduction systems used in listening tests performed in non-laboratory conditions, i.e., when such tests are distributed through the means of electronic communication and performed in a home environment. Moreover, a larger pool of potential test subjects can be reached in this manner. The perception of what the “normal” level of reproduced speech should be was examined through a listening experiment by letting the listeners set the level of reproduced speech samples as they saw fit, depending on the used sound reproduction system, the (non)existence of visual stimulus, and the voice of the speaker. The results show that the perception of normal speech level is highly individual when it comes to setting that level by listening to reproduced speech. The interindividual differences between the subjects are considerably larger than the impact of the three main effects. The understanding of what the “normal” level of read speech should be was examined experimentally as well by asking the subjects to read a paragraph of text, depending on the visual stimulus. The results show that the “normal” level of read speech is reasonably consistent and averages at 55 dBA at a normal conversational distance of 1 m, in a room with room acoustics conditions typical for home environment and low background noise, and with the visual stimulus that mimics the interlocutor put within the personal space of the reader. A preliminary proposal is given of a level calibration method for non-laboratory listening experiments based on these results, and some of its aspects that require further research are discussed.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika, Interdisciplinarne tehničke znanosti



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Poveznice na cjeloviti tekst rada:

doi www.mdpi.com

Citiraj ovu publikaciju:

Kisić, Dominik; Horvat, Marko; Jambrošić, Kristian; Franček, Petar
The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups // Applied Sciences-Basel, 12 (2022), 14; 7202, 17 doi:10.3390/app12147202 (međunarodna recenzija, članak, znanstveni)
Kisić, D., Horvat, M., Jambrošić, K. & Franček, P. (2022) The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups. Applied Sciences-Basel, 12 (14), 7202, 17 doi:10.3390/app12147202.
@article{article, author = {Kisi\'{c}, Dominik and Horvat, Marko and Jambro\v{s}i\'{c}, Kristian and Fran\v{c}ek, Petar}, year = {2022}, pages = {17}, DOI = {10.3390/app12147202}, chapter = {7202}, keywords = {listening tests, non-laboratory environment, online/home test setup, level calibration, speech}, journal = {Applied Sciences-Basel}, doi = {10.3390/app12147202}, volume = {12}, number = {14}, issn = {2076-3417}, title = {The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups}, keyword = {listening tests, non-laboratory environment, online/home test setup, level calibration, speech}, chapternumber = {7202} }
@article{article, author = {Kisi\'{c}, Dominik and Horvat, Marko and Jambro\v{s}i\'{c}, Kristian and Fran\v{c}ek, Petar}, year = {2022}, pages = {17}, DOI = {10.3390/app12147202}, chapter = {7202}, keywords = {listening tests, non-laboratory environment, online/home test setup, level calibration, speech}, journal = {Applied Sciences-Basel}, doi = {10.3390/app12147202}, volume = {12}, number = {14}, issn = {2076-3417}, title = {The potential of speech as the calibration sound for level calibration of non-laboratory listening test setups}, keyword = {listening tests, non-laboratory environment, online/home test setup, level calibration, speech}, chapternumber = {7202} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font