Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1204887

Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine


Buljac, Maša; Krivić, Denis; Škugor Rončević, Ivana; Vladislavić, Nives; Buzuk, Marijo
Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine // Chemosensors, 10 (2022), 7; 240-253 doi:10.3390/chemosensors10070240 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1204887 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine

Autori
Buljac, Maša ; Krivić, Denis ; Škugor Rončević, Ivana ; Vladislavić, Nives ; Buzuk, Marijo

Izvornik
Chemosensors (2227-9040) 10 (2022), 7; 240-253

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
electroanalysis ; cysteine ; differential pulse voltammetry ; carbon paste electrodes ; ternary sulphides ; intrinsic silver

Sažetak
In this paper, the electrochemical behavior of cysteine is described, using carbon paste electrodes (CPEs) modified with ternary silver-copper sulfide containing intrinsic silver at two pH values (pH 3 and 5). Experiments have revealed that presence of cysteine has a large impact on the electrochemical behavior of modified CPEs. Observed phenomena take place in solution, as well as at the surface of the modified CPEs, and can be applied for electroanalytical purposes. Based on the electrochemical behavior observed in the examined system, differential pulse voltammetry (DPV) was selected as an electroanalytical method for determination of cysteine. The effects of the various parameters on the electroanalytical signal, such as the amount of electroactive material, electroanalytical parameters, pH etc., were investigated using differential pulse voltammograms. The results indicated that electrochemical signal characterized with well-defined cathodic peak at 0.055 V vs. Ag/AgCl (3 M) in acetic buffer solution at pH 5 can be used for indirect electrochemical determination of cysteine. The optimization procedure revealed that the most sensitive and stabile electrode was that containing 5% modifier. The DPV response of the electrode, in the presence of cysteine, showed two different linear concentration ranges of 0.1 to 2.5 µM, and 5.6 to 28 µM. The explanation of the origin of two linear ranges is proposed. The lower concentration range was characterized by remarkable sensitivity of the 11.78 µA µM−1, owing to the chosen indirect method of determination. The calculated limit of detection (LOD), as well as limit of quantification (LOQ) were 0.032 and 0.081 µM, respectively. The influence of interfering agents on the electroanalytical response was examined, and low or no interference on the DPVs was observed. The proposed method was validated and applied for the determination of cysteine in pharmaceutical preparations with satisfactory recoveries in the range of 97 to 101.7%

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Ustanove:
Kemijsko-tehnološki fakultet, Split

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Buljac, Maša; Krivić, Denis; Škugor Rončević, Ivana; Vladislavić, Nives; Buzuk, Marijo
Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine // Chemosensors, 10 (2022), 7; 240-253 doi:10.3390/chemosensors10070240 (međunarodna recenzija, članak, znanstveni)
Buljac, M., Krivić, D., Škugor Rončević, I., Vladislavić, N. & Buzuk, M. (2022) Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine. Chemosensors, 10 (7), 240-253 doi:10.3390/chemosensors10070240.
@article{article, author = {Buljac, Ma\v{s}a and Krivi\'{c}, Denis and \v{S}kugor Ron\v{c}evi\'{c}, Ivana and Vladislavi\'{c}, Nives and Buzuk, Marijo}, year = {2022}, pages = {240-253}, DOI = {10.3390/chemosensors10070240}, keywords = {electroanalysis, cysteine, differential pulse voltammetry, carbon paste electrodes, ternary sulphides, intrinsic silver}, journal = {Chemosensors}, doi = {10.3390/chemosensors10070240}, volume = {10}, number = {7}, issn = {2227-9040}, title = {Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine}, keyword = {electroanalysis, cysteine, differential pulse voltammetry, carbon paste electrodes, ternary sulphides, intrinsic silver} }
@article{article, author = {Buljac, Ma\v{s}a and Krivi\'{c}, Denis and \v{S}kugor Ron\v{c}evi\'{c}, Ivana and Vladislavi\'{c}, Nives and Buzuk, Marijo}, year = {2022}, pages = {240-253}, DOI = {10.3390/chemosensors10070240}, keywords = {electroanalysis, cysteine, differential pulse voltammetry, carbon paste electrodes, ternary sulphides, intrinsic silver}, journal = {Chemosensors}, doi = {10.3390/chemosensors10070240}, volume = {10}, number = {7}, issn = {2227-9040}, title = {Voltammetric Electrochemical Behavior of Carbon Paste Electrode Containing Intrinsic Silver for Determination of Cysteine}, keyword = {electroanalysis, cysteine, differential pulse voltammetry, carbon paste electrodes, ternary sulphides, intrinsic silver} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font