Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1197220

High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry


Vila-Comamala, Joan; Romano, Lucia; Jefimovs, Konstantins; Dejea, Hector; Bonnin, Ann; Cook, Andrew C.; Planinc, Ivo; Čikes, Maja; Wang, Zhentian; Stampanoni, Marco
High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry // Optics express, 29 (2021), 2; 2049-2064 doi:10.1364/OE.414174 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1197220 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry

Autori
Vila-Comamala, Joan ; Romano, Lucia ; Jefimovs, Konstantins ; Dejea, Hector ; Bonnin, Ann ; Cook, Andrew C. ; Planinc, Ivo ; Čikes, Maja ; Wang, Zhentian ; Stampanoni, Marco

Izvornik
Optics express (1094-4087) 29 (2021), 2; 2049-2064

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
tomography ; microtomography

Sažetak
X-ray phase contrast imaging is a powerful analysis technique for materials science and biomedicine. Here, we report on laboratory grating-based X-ray interferometry employing a microfocus X-ray source and a high Talbot order (35th) asymmetric geometry to achieve high angular sensitivity and high spatial resolution X-ray phase contrast imaging in a compact system (total length <1 m). The detection of very small refractive angles (∼50 nrad) at an interferometer design energy of 19 keV was enabled by combining small period X-ray gratings (1.0, 1.5 and 3.0 µm) and a single-photon counting X-ray detector (75 µm pixel size). The performance of the X-ray interferometer was fully characterized in terms of angular sensitivity and spatial resolution. Finally, the potential of laboratory X-ray phase contrast for biomedical imaging is demonstrated by obtaining high resolution X-ray phase tomographies of a mouse embryo embedded in solid paraffin and a formalin-fixed full-thickness sample of human left ventricle in water with a spatial resolution of 21.5 µm.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb

Profili:

Avatar Url Maja Čikeš (autor)

Avatar Url Ivo Planinc (autor)

Poveznice na cjeloviti tekst rada:

doi opg.optica.org

Citiraj ovu publikaciju:

Vila-Comamala, Joan; Romano, Lucia; Jefimovs, Konstantins; Dejea, Hector; Bonnin, Ann; Cook, Andrew C.; Planinc, Ivo; Čikes, Maja; Wang, Zhentian; Stampanoni, Marco
High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry // Optics express, 29 (2021), 2; 2049-2064 doi:10.1364/OE.414174 (međunarodna recenzija, članak, znanstveni)
Vila-Comamala, J., Romano, L., Jefimovs, K., Dejea, H., Bonnin, A., Cook, A., Planinc, I., Čikes, M., Wang, Z. & Stampanoni, M. (2021) High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry. Optics express, 29 (2), 2049-2064 doi:10.1364/OE.414174.
@article{article, author = {Vila-Comamala, Joan and Romano, Lucia and Jefimovs, Konstantins and Dejea, Hector and Bonnin, Ann and Cook, Andrew C. and Planinc, Ivo and \v{C}ikes, Maja and Wang, Zhentian and Stampanoni, Marco}, year = {2021}, pages = {2049-2064}, DOI = {10.1364/OE.414174}, keywords = {tomography, microtomography}, journal = {Optics express}, doi = {10.1364/OE.414174}, volume = {29}, number = {2}, issn = {1094-4087}, title = {High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry}, keyword = {tomography, microtomography} }
@article{article, author = {Vila-Comamala, Joan and Romano, Lucia and Jefimovs, Konstantins and Dejea, Hector and Bonnin, Ann and Cook, Andrew C. and Planinc, Ivo and \v{C}ikes, Maja and Wang, Zhentian and Stampanoni, Marco}, year = {2021}, pages = {2049-2064}, DOI = {10.1364/OE.414174}, keywords = {tomography, microtomography}, journal = {Optics express}, doi = {10.1364/OE.414174}, volume = {29}, number = {2}, issn = {1094-4087}, title = {High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry}, keyword = {tomography, microtomography} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font