Pregled bibliografske jedinice broj: 1195179
New dynamometric parameters in evaluation of hand function in rheumatoid arthritis based on dynamic measurements – a pilot evaluation study
New dynamometric parameters in evaluation of hand function in rheumatoid arthritis based on dynamic measurements – a pilot evaluation study // Clin Exp Rheumatol
Genova, Italija, 2018. str. S-82 (poster, podatak o recenziji nije dostupan, sažetak, znanstveni)
CROSBI ID: 1195179 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
New dynamometric parameters in evaluation of hand
function in rheumatoid arthritis based on dynamic
measurements – a pilot evaluation study
Autori
Doko, Ines ; Dubravić, Amir ; Michieli, Ivan ; Medved Rogina, Branka ; Grazio, Simeon
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Clin Exp Rheumatol
/ - , 2018, S-82
Skup
17th Mediterranean Congress of Rheumatology
Mjesto i datum
Genova, Italija, 12.04.2018. - 14.04.2018
Vrsta sudjelovanja
Poster
Vrsta recenzije
Podatak o recenziji nije dostupan
Ključne riječi
dynamometer ; rehabilitation ; grip force
Sažetak
Objective. In rheumatoid arthritis (RA) inflammation and damage lead to functional impairment. The hand is a typical site of the involvement, and therefore lower grip strength is often found in these patients. Better detailing of evaluation parameters such as the velocity and stability of hand grip in relation to present static measurements of grip force might be helpful for rehabilitation evaluation of the hand. The aim of this paper was to produce an analysis and interpretation method for measured data using a specially designed electrodynamometer that gives an objective and a more detailed evaluation of the functional state of the hand. Design and Method. An expert electronic measuring system for obtaining dynamic time series of the hand grip force was developed. We tested it in the sample of 24 participants, 12 patients with RA and 12 age- and sex-matched healthy controls. The main dynamometric parameters obtained were: maximal grip force, fatigue, grip velocity, functional potential. These were measured at the baseline and at 60, 120 and 180 days. Results. Compared to the control group, the patients with RA had significantly lower maximal grip force (68.2 vs. 97.3), sooner occurrence of fatigue (22.4 vs. 24.9), lower grip velocity (14.8 vs. 22.2) and functional potential (808.2 vs. 1876.3) at the baseline. The significant improvement in all measured variables was observed during the follow-up period. Conclusions. In our pilot-study we tested a new- developed electrodynamometer measuring system and found that it can demonstrate hand condition objectively and in details. This system has a potential to be used as a relevant indicator of hand function in patients with RA and to help tailor their rehabilitation.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)
POVEZANOST RADA
Ustanove:
KBC "Sestre Milosrdnice"
Profili:
Branka Medved-Rogina
(autor)
Amir Dubravić
(autor)
Ines Doko Vajdić
(autor)
Ivan Michieli
(autor)
Simeon Grazio
(autor)