P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study


Petrovic, B.; Faj, D.; Markovic, M.; Paunovic, D; Stankovic, J; Krestic-Vesovic, J.; Miskovic, I; Cicarevic, K.; Kasabasic, M., Bibic, J.; Budanec, M. et al.
P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study // Physica medica, 92, Supplement (2021), S1-S282 doi:10.1016/S1120-1797(22)00375-1 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1195114 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study

Autori
Petrovic, B. ; Faj, D. ; Markovic, M. ; Paunovic, D ; Stankovic, J ; Krestic-Vesovic, J. ; Miskovic, I ; Cicarevic, K. ; Kasabasic, M., Bibic, J. ; Budanec, M. ; Kralik, I. ; Galic S. ; Hrepic, D. ; Ibrisimovic, L. ; Davidovic, J. ; Kolarevic, G. ; Novakovic, T.

Izvornik
Physica medica (1120-1797) 92, Supplement (2021); S1-S282

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
CT simulator, radiotherapy, conversion curve CT-to-ED

Sažetak
Results: Field size differences were below 1 mm for all applicators and energies, except for the 2 cm applicator (the smallest one), for which the array error was 5 mm. The penumbrae were systematically larger (differences ranging from 1.6 mm to 4.1 mm) when measured using Starcheck. The symmetry values measured with the array agreed for applicators greater than 6 cm. Conclusions: The Starcheck array is suitable for the profile analysis of low-energy x-ray units with some limitations. The lower resolution of the matrix against films results in a smoothing of all profiles (figure). This effect increases when the applicator size decreases. It affects the values of the penumbra and the symmetry but not the field size except for the 2 cm applicator. Still, it can be used for constancy checks if properly referenced to films.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Dario Faj (autor)

Avatar Url Ivana Kralik (autor)

Avatar Url Mirjana Budanec (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Petrovic, B.; Faj, D.; Markovic, M.; Paunovic, D; Stankovic, J; Krestic-Vesovic, J.; Miskovic, I; Cicarevic, K.; Kasabasic, M., Bibic, J.; Budanec, M. et al.
P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study // Physica medica, 92, Supplement (2021), S1-S282 doi:10.1016/S1120-1797(22)00375-1 (međunarodna recenzija, članak, znanstveni)
Petrovic, B., Faj, D., Markovic, M., Paunovic, D., Stankovic, J., Krestic-Vesovic, J., Miskovic, I., Cicarevic, K., Kasabasic, M., Bibic, J. & Budanec, M. (2021) P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study. Physica medica, 92, Supplement, S1-S282 doi:10.1016/S1120-1797(22)00375-1.
@article{article, author = {Petrovic, B. and Faj, D. and Markovic, M. and Paunovic, D and Stankovic, J and Krestic-Vesovic, J. and Miskovic, I and Cicarevic, K. and Budanec, M. and Kralik, I. and Hrepic, D. and Ibrisimovic, L. and Davidovic, J. and Kolarevic, G. and Novakovic, T.}, year = {2021}, pages = {S1-S282}, DOI = {10.1016/S1120-1797(22)00375-1}, keywords = {CT simulator, radiotherapy, conversion curve CT-to-ED}, journal = {Physica medica}, doi = {10.1016/S1120-1797(22)00375-1}, volume = {92, Supplement}, issn = {1120-1797}, title = {P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study}, keyword = {CT simulator, radiotherapy, conversion curve CT-to-ED} }
@article{article, author = {Petrovic, B. and Faj, D. and Markovic, M. and Paunovic, D and Stankovic, J and Krestic-Vesovic, J. and Miskovic, I and Cicarevic, K. and Budanec, M. and Kralik, I. and Hrepic, D. and Ibrisimovic, L. and Davidovic, J. and Kolarevic, G. and Novakovic, T.}, year = {2021}, pages = {S1-S282}, DOI = {10.1016/S1120-1797(22)00375-1}, keywords = {CT simulator, radiotherapy, conversion curve CT-to-ED}, journal = {Physica medica}, doi = {10.1016/S1120-1797(22)00375-1}, volume = {92, Supplement}, issn = {1120-1797}, title = {P73 - Assessment of different CT simulators used in radiotherapy treatment planning: regional multicentric study}, keyword = {CT simulator, radiotherapy, conversion curve CT-to-ED} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font