Pregled bibliografske jedinice broj: 1195007
Transcatheter aortic valve implantation induces transient drop in platelet reactivity
Transcatheter aortic valve implantation induces transient drop in platelet reactivity // Journal of cardiovascular pharmacology, 78 (2021), 2; 263-268 doi:10.1097/FJC.0000000000001056 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1195007 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Transcatheter aortic valve implantation induces
transient drop in platelet reactivity
Autori
Ostojić, Zvonimir ; Bulum, Joško ; Samardžić, Jure ; Pavasović, Saša ; Šipuš, Dubravka ; Šafradin, Ivica ; Rešković Lukšić, Vlatka ; Skorić, Boško ; Šeparović Hanževački, Jadranka ; Miličić, Davor
Izvornik
Journal of cardiovascular pharmacology (0160-2446) 78
(2021), 2;
263-268
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
dual antiplatelet therapy ; platelet reactivity testing ; impedance aggregometry ; aortic stenosis ; transcatheter aortic valve implantation
Sažetak
Although recent studies described platelet reactivity (PR) changes in days after transcatheter aortic valve implantation (TAVI), precise time course and duration of these changes have not been fully investigated. The aim of this study was to investigate PR pattern during and after TAVI in multiple time points. Study included 40 consecutive patients undergoing TAVI. All patients underwent the procedure on dual antiplatelet therapy. PR was measured in 7 time points: before induction of anesthesia (T1), after heparin administration (T2), 10 minutes after initial valve implantation (T3), at the end of procedure (T4), and on 3rd, 6th, and 30th postoperative day (T5–T7). PR was measured using impedance aggregometer using 3 different platelet aggregation agonists (arachidonic acid in ASPItest, adenosine diphosphate in ADPtest and thrombin receptor activating peptide 6 in TRAPtest). All patients underwent successful TAVI procedure. Mean PR on T1 was 22.9 ± 23.0 U for ASPItest, 40.5 ± 23.7 U for ADPtest and 91.7 ± 32.5 U for TRAPtest. There was no significant difference in PR on T2. On T3, significant reduction of PR in all 3 tests was observed [ASPI 10.4 ± 11.6 U (P = 0.001), ADP 24.2 ± 14.1 U (P < 0.001) and TRAP 69.3 ± 26.6 U (P < 0.001)]. PR nadir for all tests was reached on T5, with subsequent PR incline. PR values in all tests returned to baseline levels on T7. Our results show that successful TAVI procedure induces transient decrease in PR regardless of the platelet activation pathway.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb
Profili:
Zvonimir Ostojić
(autor)
Boško Skorić
(autor)
Joško Bulum
(autor)
Jure Samardžić
(autor)
Davor Miličić
(autor)
Jadranka Šeparović-Hanževački
(autor)
Dubravka Šipuš
(autor)
Saša Pavasović
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE