Pregled bibliografske jedinice broj: 1186953
Karakterizacija jetrenih tumora kontrastnim ultrazvukom: rezultati iz tercijarnog centra
Karakterizacija jetrenih tumora kontrastnim ultrazvukom: rezultati iz tercijarnog centra // Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 5-6 (2018), 150-159 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1186953 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Karakterizacija jetrenih tumora kontrastnim
ultrazvukom: rezultati iz tercijarnog centra
(Characterization of liver tumors by contrast-
enhanced ultrasound: single centre experience)
Autori
Grgurević, Ivica ; Bokun, Tomislav ; Huzjan- Korunić, Renata ; Vukelić-Marković, Mirjana ; Brkljačić, Boris ; Ivanac, Gordana ; Aralica, Gorana ; Štoos-Veić, Tajana ; Lukić, Anita ; Banić, Marko ; Kujundžić, Milan
Izvornik
Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora (0024-3477) 5-6
(2018);
150-159
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
jetreni tumor ; ultrazvuk ; kontrastna sredstva ; osjetljivost ; specifičnost ; dijagnostika
(liver tumors ; constrast agents ; sensitivity ; specificity ; diagnosis)
Sažetak
Aim: To demonstrate the results of contrast-enhanced ultrasound (CEUS) for diagnostic characterization of liver tumors (LT) in a tertiary-care hospital. Patients and methods: Results of CEUS examinations of LT in successively included patients from January 1st 2015 to December 31st 2016 were retrospectively analyzed. Definite diagnosis was made through standardized clinical workup including MRI and/or MSCT, tissue sampling (biopsy or cytology) in cases when imaging was inconclusive, as well as pathohistological analysis of resected specimens in patients that underwent surgery. Results: In 90 patients (48 M, 42 F ; age 57±15) 132 LT were analyzed (68 benign and 64 malignant), with average size of 30 (8-130) mm. CEUS demonstrated excellent diagnostic performance to differentiate between benign and malignant LT (sensitivity 98.44%, specifi city 83.82%, AUC 0.91), without adverse reactions. Conclusion: Our results demonstrate high diagnostic accuracy and safety of CEUS for characterization of LT.
Izvorni jezik
Hrvatski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Opća bolnica Varaždin,
Klinička bolnica "Dubrava"
Profili:
Tomislav Bokun
(autor)
Tajana Štoos-Veić
(autor)
Gordana Ivanac
(autor)
Gorana Aralica
(autor)
Anita Lukić
(autor)
Boris Brkljačić
(autor)
Ivica Grgurević
(autor)
Renata Huzjan Korunić
(autor)
Milan Kujundžić
(autor)
Marko Banić
(autor)