Pregled bibliografske jedinice broj: 1186462
New Method for Performing Vibratory Stimulation and Detection of Early Cortical Response
New Method for Performing Vibratory Stimulation and Detection of Early Cortical Response // Jubilee Annual 2017-2018 of the Croatian Academy of Engineering / Andročec, Vladimir ; Terze, Zdravko ; Rogale, Dubravko ; Gaurina-Međimurec, Nediljka ; Krajcar, Slavko (ur.).
Zagreb: Akademija tehničkih znanosti Hrvatske (HATZ), 2018. str. 275-286
CROSBI ID: 1186462 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
New Method for Performing Vibratory Stimulation and
Detection of Early Cortical Response
Autori
Krbot Skorić, Magdalena ; Krois, Igor ; Išgum, Velimir ; Jerbić, Ana Branka ; Cifrek, Mario
Vrsta, podvrsta i kategorija rada
Poglavlja u knjigama, znanstveni
Knjiga
Jubilee Annual 2017-2018 of the Croatian Academy of Engineering
Urednik/ci
Andročec, Vladimir ; Terze, Zdravko ; Rogale, Dubravko ; Gaurina-Međimurec, Nediljka ; Krajcar, Slavko
Izdavač
Akademija tehničkih znanosti Hrvatske (HATZ)
Grad
Zagreb
Godina
2018
Raspon stranica
275-286
ISSN
1332-3482
Ključne riječi
deep sense ; vibratory sensory pathway ; vibratory stimulation ; evoked potentials ; vibratory stimulator
Sažetak
Deep sense capability is one of very important indicators of numerous pathologies in medicine, and one of the indicators of deep sense is the sense of vibration. One of the methods for testing the sense of vibration is vibratory evoked potentials, which present the response of the nervous system to vibratory stimulus. Currently used vibratory stimulation has small clinical value because obtained results do not incorporate quantifiable information about entire afferent activity of vibratory sensory pathway (VSP), and response appears around 50 ms, providing no information about early cortical activity. The aim of this research was to develop a method of vibratory stimulation that would provide information about the functional integrity of the whole VSP. The impossibility of monitoring the function of the whole VSP is related to changes in stimulation parameters between successive stimuli and because of that the basic premise of evoked potentials (equal parameters for every stimulus) is disrupted. Vibratory stimulator with controllable pressure of vibratory applicator was constructed in order to provide equal parameters for every stimulus to obtain quantifiable information about entire VSP. Optimum parameters of stimulation were chosen (stimulus frequency of 120 Hz, stimulus duration of 50 ms, and wrist as the site of stimulation).
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Računarstvo
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Klinički bolnički centar Zagreb
Profili:
Velimir Išgum (autor)
Igor Krois (autor)
Ana Branka Jerbić (autor)
MAGDALENA KRBOT SKORIĆ (autor)
Mario Cifrek (autor)