Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1186017

Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection


Zhang, Xiaotao; Wei, Yi; Wu, Huihuang; Yan, Hongli; Liu, Yiming; Lučev Vasić, Željka; Pan, Haibo; Cifrek, Mario; Du, Min; Gao, Yueming
Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection // Electroanalysis, 34 (2022), 9; 1411-1421 doi:10.1002/elan.202100674 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1186017 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection

Autori
Zhang, Xiaotao ; Wei, Yi ; Wu, Huihuang ; Yan, Hongli ; Liu, Yiming ; Lučev Vasić, Željka ; Pan, Haibo ; Cifrek, Mario ; Du, Min ; Gao, Yueming

Izvornik
Electroanalysis (1040-0397) 34 (2022), 9; 1411-1421

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Portable potentiostat ; Smartphone ; Cyclic voltammetry ; Screen-printed electrode ; Nonenzyme

Sažetak
On-site quantitative detection provides the opportunity for accurate and timely health care, clinical diagnosis, environmental monitoring, and food analysis. A variety of portable electrochemical detection instruments have been developed at present for on-site quantitative detection use, including commercially available portable potentiostats, but the reality is that these electrochemical detection devices still have the problem of narrow output voltage range and detection current range, and their performance of output voltage resolution and detection current resolution is still unsatisfactory. The narrow voltage or current range makes it difficult for some chemical reactions with peaks outside the range to proceed, and the insufficiency of voltage resolution and detection current resolution are key parameters restricting the detection accuracy of existing devices. In this regard, it is urgent to carry out partial transformation of the existing device to increase the use range and detection accuracy of the device. In the current work, a smartphone-based electrochemical on-site quantitative detection device was developed. The device comprises a portable small potentiostat, a smartphone equipped with a specially designed Android electrochemical detection application, and a disposable sensor (NiONP modified screen-printed electrode [SPE]). The potentiostat can realize electrochemical detection methods, including cyclic voltammetry, chronoamperometry, and differential pulse voltammetry. In addition, the potentiostat can output a potential range − 2.047 ~ + 2.047 V with a current detection sensitivity scale 1×10−8 ~ 1×10−3 A, and the current detection range could reach ±10 nA ~ ±10 mA. Most importantly, the current detection resolution of the potentiostat can reach 0.003% (3.125 pA on ± 10 nA range). The smartphone was used for communicating with the potentiostat, setting detection parameters, and mapping voltammograms in real time. The SPE was modified with nickel oxide nanoparticles and perfluorinated resin solution, which were employed as sensors to convert and amplify the electrochemical current response during the on-site quantitative detection. Results indicated that the device features excellent performance for the lactate detection. The device covered a linear range 0.1 ~ 30 mM on lactate detection with the correlation coefficient (R2) reaching 0.997.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Mario Cifrek (autor)

Avatar Url Željka Lučev Vasić (autor)

Poveznice na cjeloviti tekst rada:

doi analyticalsciencejournals.onlinelibrary.wiley.com

Poveznice na istraživačke podatke:

github.com

Citiraj ovu publikaciju:

Zhang, Xiaotao; Wei, Yi; Wu, Huihuang; Yan, Hongli; Liu, Yiming; Lučev Vasić, Željka; Pan, Haibo; Cifrek, Mario; Du, Min; Gao, Yueming
Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection // Electroanalysis, 34 (2022), 9; 1411-1421 doi:10.1002/elan.202100674 (međunarodna recenzija, članak, znanstveni)
Zhang, X., Wei, Y., Wu, H., Yan, H., Liu, Y., Lučev Vasić, Ž., Pan, H., Cifrek, M., Du, M. & Gao, Y. (2022) Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection. Electroanalysis, 34 (9), 1411-1421 doi:10.1002/elan.202100674.
@article{article, author = {Zhang, Xiaotao and Wei, Yi and Wu, Huihuang and Yan, Hongli and Liu, Yiming and Lu\v{c}ev Vasi\'{c}, \v{Z}eljka and Pan, Haibo and Cifrek, Mario and Du, Min and Gao, Yueming}, year = {2022}, pages = {1411-1421}, DOI = {10.1002/elan.202100674}, keywords = {Portable potentiostat, Smartphone, Cyclic voltammetry, Screen-printed electrode, Nonenzyme}, journal = {Electroanalysis}, doi = {10.1002/elan.202100674}, volume = {34}, number = {9}, issn = {1040-0397}, title = {Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection}, keyword = {Portable potentiostat, Smartphone, Cyclic voltammetry, Screen-printed electrode, Nonenzyme} }
@article{article, author = {Zhang, Xiaotao and Wei, Yi and Wu, Huihuang and Yan, Hongli and Liu, Yiming and Lu\v{c}ev Vasi\'{c}, \v{Z}eljka and Pan, Haibo and Cifrek, Mario and Du, Min and Gao, Yueming}, year = {2022}, pages = {1411-1421}, DOI = {10.1002/elan.202100674}, keywords = {Portable potentiostat, Smartphone, Cyclic voltammetry, Screen-printed electrode, Nonenzyme}, journal = {Electroanalysis}, doi = {10.1002/elan.202100674}, volume = {34}, number = {9}, issn = {1040-0397}, title = {Smartphone-based electrochemical on-site quantitative detection device for nonenzyme lactate detection}, keyword = {Portable potentiostat, Smartphone, Cyclic voltammetry, Screen-printed electrode, Nonenzyme} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font