Pregled bibliografske jedinice broj: 1168726
Patient exposure dose in interventional cardiology per clinical and technical complexity levels. Part 1: results of the VERIDIC project
Patient exposure dose in interventional cardiology per clinical and technical complexity levels. Part 1: results of the VERIDIC project // Acta radiologica, / (2021), x-x doi:10.1177/02841851211061438 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1168726 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Patient exposure dose in interventional
cardiology per clinical and technical
complexity levels. Part 1: results of the
VERIDIC project
Autori
Feghali, Joelle Ann ; Delépierre, Julie ; Ciraj Bjelac, Olivera ; Dabin, Jérémie, Deleu, Marine ; De Monte, Francesca ; Dobrić, Milan ; Gallagher, Aoife ; Hadid-Beurrier, Lama ; Henry, Patrick ; Hršak, Hrvoje ; Kiernan, Tom ; Rajesh, Kumar ; Knežević, Željka ; Maccia, Carlo ; Majer, Marija ; Malchair, Françoise ; Noble, Stéphane ; Obrad, Davor ; Sans Merce, Marta ; Sideris, Georgios ; Simantirakis, G ; Spaulding, Christian ; Tarantini, Giussepe ; Van Ngoc Ty, Claire
Izvornik
Acta radiologica (0284-1851)
(2021);
X-x
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Interventional cardiology ; peak skin dose ; diagnostic reference levels ; VERIDIC
Sažetak
Background: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. Purpose: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. Material and Methods: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) pro- ject analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) pro- cedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, uni- variate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Interdisciplinarne prirodne znanosti, Kliničke medicinske znanosti
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE