Pregled bibliografske jedinice broj: 1161939
Assessment of computed tomography simulators used in radiotherapy treatment planning in Serbia, Croatia, and Bosnia and Herzegovina
Assessment of computed tomography simulators used in radiotherapy treatment planning in Serbia, Croatia, and Bosnia and Herzegovina // Nuclear Technology and Radiation Protection, 36 (2021), 1; 97-106 doi:10.2298/ntrp201118009p (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1161939 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Assessment of computed tomography simulators used in radiotherapy treatment planning in Serbia, Croatia, and Bosnia and Herzegovina
Autori
Petrovic, Borislava ; Faj, Dario ; Markovic, Mladen ; Tot, Arpad ; Marjanovic, Milana ; Kasabasic, Mladen ; Gencel, Ivan ; Paunovic, Dragomir ; Stankovic, Jelena ; Krestic-Vesovic, Jelena ; Miskovic, Ivana ; Cicarevic, Koca ; Bibic, Juraj ; Budanec, Mirjana ; Kralik, Ivana ; Galic, Stipe ; Hrepic, Darijo ; Ibrisimovic, Lejla ; Davidovic, Jasna ; Kolarevic, Goran
Izvornik
Nuclear Technology and Radiation Protection (1451-3994) 36
(2021), 1;
97-106
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
CT simulator, QC, CT-to-ED
Sažetak
The purpose of this work was to evaluate computed tomography simulators used in radio-therapy treatment planning in Serbia, Croatia, and Bosnia and Herzegovina. A survey of quality assurance programmes of 24 computed tomography simulators in 16 facilities was conducted. A dedicated CT-to-ED phantom was scanned at 120 kV and 140 kV, to obtain CT-to-ED conversion curves as well as CTDIvol. Thoracal phantoms were scanned in the standard and extended field of view to evaluate the dosimetric effect on treatment planning and delivery. The mean age of the measured scanners was 5.5 years. The mean water HU value was ?6.5 (all scanners, all voltages) and air HU value was ?997. Extended field of view computed tomography data differ from the standard field of view and differences between conversion curves have significant dosimetric impact. The CTDI data showed a large range of values between centers. Better quality assurance of computed tomography simulators in all countries is recommended. The CT-to-ED curve could be used as default at one voltage and per manufacturer. Extended field of view imaging can be used, but treatment planning should be avoided in the regions out of the standard field of view.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinički bolnički centar Osijek,
KBC "Sestre Milosrdnice",
KBC Split,
Klinički bolnički centar Zagreb,
Medicinski fakultet, Split,
Medicinski fakultet, Osijek,
Fakultet za dentalnu medicinu i zdravstvo, Osijek
Profili:
Ivana Kralik
(autor)
Mirjana Budanec
(autor)
Stipe Galić
(autor)
Ivana Mišković
(autor)
Mladen Marković
(autor)
Mladen Kasabašić
(autor)
Dario Faj
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus