Imaging of Organic Samples with Megaelectron Volt Time-of-Flight Secondary Ion Mass Spectrometry Capillary Microprobe
Imaging of Organic Samples with Megaelectron Volt Time-of-Flight Secondary Ion Mass Spectrometry Capillary Microprobe // Journal of the American Society for Mass Spectrometry, 32 (2021), 10; 2567-2572 doi:10.1021/jasms.1c00200 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1151131 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Imaging of Organic Samples with Megaelectron Volt
Time-of-Flight Secondary Ion Mass Spectrometry
Capillary Microprobe
Autori
Brajković, Marko ; Bogdanović Radović, Ivančica ; Barac, Marko ; Cosic, Donny Domagoj ; Siketić, Zdravko
Izvornik
Journal of the American Society for Mass Spectrometry (1044-0305) 32
(2021), 10;
2567-2572
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
MeV TOF-SIMS ; capillary microprobe ; imaging applications ; start trigger ; secondary electrons
Sažetak
Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) with MeV primary ions offers a fine balance between secondary ion yield for molecules in the mass range from 100 to 1000 Da and beam spot size, both of which are critical for imaging applications of organic samples. Using conically shaped glass capillaries with an exit diameter of a few micrometers, a high energy heavy primary beam can be collimated to less than 10 μm. In this work, imaging capabilities of such a setup are presented for some organic samples (leucine- evaporated mesh, fly wing section, ink deposited on paper). Lateral resolution measurement and molecular distributions of selected mass peaks are shown. The negative influence of the beam halo, an unavoidable characteristic of primary beam collimation with a conical capillary, is also discussed. A new start trigger for TOF measurements based on the detection of secondary electrons released by the primary ion is presented. This method is applicable for a continuous primary ion beam, and for thick targets that are not transparent to the primary ion beam. The solution preserves the good mass resolution of the thin target setup, where the detection of primary ions with a PIN diode is used for a start trigger, reduces the background, and enables a wide range of samples to be analyzed.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
POVEZANOST RADA
Projekti:
HRZZ-IP-2016-06-1698 - Razvoj kapilarne mikroprobe za MeV SIMS s primjenom na analizu bioloških materijala (BioCapSIMS) (Bogdanović Radović, Ivančica, HRZZ - 2016-06) ( CroRIS)
EK-824096 - Istraživanje i razvoj s ionskim zrakama – unaprjeđenje tehnologije u Europi (RADIATE) (Bogdanović Radović, Ivančica, EK ) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb
Profili:
Ivančica Bogdanović Radović
(autor)
Donny Domagoj Cosic
(autor)
Zdravko Siketić
(autor)
Marko Barac
(autor)
Marko Brajković
(autor)
Poveznice na cjeloviti tekst rada:
doi pubs.acs.org doi.orgPoveznice na istraživačke podatke:
urn.nsk.hrCitiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE