Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements


Pavičić, Ivan; Holjevac, Ninoslav; Ivanković, Igor; Brnobić, Dalibor
Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements // Energies, 14 (2021), 17; 5562, 25 doi:10.3390/en14175562 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1150828 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements

Autori
Pavičić, Ivan ; Holjevac, Ninoslav ; Ivanković, Igor ; Brnobić, Dalibor

Izvornik
Energies (1996-1073) 14 (2021), 17; 5562, 25

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
transmission line losses ; synchrophasor (PMU) measurements ; metering data ; corona losses

Sažetak
Abstract: This paper presents an advanced model for monitoring losses on a 400 kV over-head transmission line (OHL) that can be used for measured data verification and loss assessment. Technical losses are unavoidable physical effects of energy transmission and can be reduced to acceptable levels, with a major share of technical losses on transmission lines being Joule losses. However, at 400 kV voltage levels, the influence of the electrical corona discharge effect and current leakage can have significant impact on power loss. This is especially visible in poor weather conditions, such as the appearance of fog, rain and snow. Therefore, loss monitoring is incorporated into exiting business process to provide transmission system operators (TSO) with the measure of losses and the accurate characterization of measured data. This paper presents an advanced model for loss characterization and assessment that uses phasor measurement unit (PMU) measurements and combines them with end-customer measurements. PMU measurements from the algorithm of differential protection are used to detect differential currents and angles, and this paper proposes further usage of these data for determining the corona losses. The collected data are further processed and used to calculate the amount of corona losses and provide accurate loss assessment and estimation. In each step of the model, cross verification of the measured and calculated data is performed in order to finally provide more accurate loss assessment which is incorporated into the current data acquisition and monitoring systems.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Poveznice na cjeloviti tekst rada:

doi www.mdpi.com

Citiraj ovu publikaciju:

Pavičić, Ivan; Holjevac, Ninoslav; Ivanković, Igor; Brnobić, Dalibor
Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements // Energies, 14 (2021), 17; 5562, 25 doi:10.3390/en14175562 (međunarodna recenzija, članak, znanstveni)
Pavičić, I., Holjevac, N., Ivanković, I. & Brnobić, D. (2021) Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements. Energies, 14 (17), 5562, 25 doi:10.3390/en14175562.
@article{article, author = {Pavi\v{c}i\'{c}, Ivan and Holjevac, Ninoslav and Ivankovi\'{c}, Igor and Brnobi\'{c}, Dalibor}, year = {2021}, pages = {25}, DOI = {10.3390/en14175562}, chapter = {5562}, keywords = {transmission line losses, synchrophasor (PMU) measurements, metering data, corona losses}, journal = {Energies}, doi = {10.3390/en14175562}, volume = {14}, number = {17}, issn = {1996-1073}, title = {Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements}, keyword = {transmission line losses, synchrophasor (PMU) measurements, metering data, corona losses}, chapternumber = {5562} }
@article{article, author = {Pavi\v{c}i\'{c}, Ivan and Holjevac, Ninoslav and Ivankovi\'{c}, Igor and Brnobi\'{c}, Dalibor}, year = {2021}, pages = {25}, DOI = {10.3390/en14175562}, chapter = {5562}, keywords = {transmission line losses, synchrophasor (PMU) measurements, metering data, corona losses}, journal = {Energies}, doi = {10.3390/en14175562}, volume = {14}, number = {17}, issn = {1996-1073}, title = {Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements}, keyword = {transmission line losses, synchrophasor (PMU) measurements, metering data, corona losses}, chapternumber = {5562} }