Pregled bibliografske jedinice broj: 1148501
Fingerprinting Mean Composition of Lithium Polysulfide Standard Solutions by Applying High-Energy Resolution Fluorescence Detected X-ray Absorption Spectroscopy
Fingerprinting Mean Composition of Lithium Polysulfide Standard Solutions by Applying High-Energy Resolution Fluorescence Detected X-ray Absorption Spectroscopy // The Journal of Physical Chemistry Letters, 11 (2020), 14; 5446-5450 doi:10.1021/acs.jpclett.0c01120 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1148501 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Fingerprinting Mean Composition of Lithium Polysulfide Standard Solutions by Applying High-Energy Resolution Fluorescence Detected X-ray Absorption Spectroscopy
Autori
Robba, A. ; Barchasz, C. ; Bučar, K. ; Petric, M. ; Žitnik, M. ; Kvashnina, K. ; Vaughan, G. B. M. ; Bouchet, R. ; Alloin, F. ; Kavčič, M.
Izvornik
The Journal of Physical Chemistry Letters (1948-7185) 11
(2020), 14;
5446-5450
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Energy, Sulfur, Batteries, Absorption, Lithium
Sažetak
In a lithium/sulfur (Li/S) battery, the reduction of sulfur during discharge involves a particular mechanism, where the active material successively dissolves into the electrolyte to form lithium polysulfide intermediate species (Li2Sx), with x being a function of the state of charge. In this work, sulfur K-edge resonant inelastic X-ray scattering measurements were performed for the characterization of different Li2Sx polysulfide standard solutions. High-energy resolution fluorescence detected X-ray absorption spectroscopy allowed clear separation the pre-edge absorption peak corresponding to terminal sulfur atoms from the main absorption peak due to internal atoms and allowed quantitative evaluation of the evolution of the peak area ratio as a function of the polysulfide chain length. Results of this experimental work demonstrate that the normalized area of the pre-edge is a reliable fingerprint of the Li2Sx mean chain length in agreement with recent theoretical predictions. As a perspective, this work confirms that operando HERFD XAS can be used to differentiate mean polysulfide composition, which is key issue in the characterization of Li/S cells.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemija
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
- Nature Index