Different screw fixation placements in treating of Pauwels type III femoral neck fractures: A finite element study
Different screw fixation placements in treating of Pauwels type III femoral neck fractures: A finite element study // Book of Abstracts 37th Danubia Adria Symposium on Advances in Experimental Mechanics / Holl, Helmut J. (ur.).
Linz: Johannes Kepler University, Institute of Technical Mechanics, 2021. str. 155-156 (predavanje, međunarodna recenzija, prošireni sažetak, znanstveni)
CROSBI ID: 1145891 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Different screw fixation placements in treating
of Pauwels type III femoral neck fractures: A
finite element study
Autori
Adamović, Petra ; Kodvanj, Janoš ; Sabalić, Srećko
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, prošireni sažetak, znanstveni
Izvornik
Book of Abstracts 37th Danubia Adria Symposium on Advances in Experimental Mechanics
/ Holl, Helmut J. - Linz : Johannes Kepler University, Institute of Technical Mechanics, 2021, 155-156
ISBN
978-3-9504997-0-4
Skup
37th Danubia Adria Symposium on Advances in Experimental Mechanics
Mjesto i datum
Linz, Austrija, 21.09.2021. - 24.09.2021
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
finite element analysis ; biomechanical stability ; inverted triangle ; femoral neck fracture ; Pauwels Type III
Sažetak
Intracapsular hip fractures in the young patients are typically a high energy injury fractures which are commonly known as Pauwels type III femoral neck fractures. Artificial head replacement surgery is usually not considered for treating femoral neck fractures in such patients. The commonly used devices for fixation of vertical femoral neck fractures are multiple screws or a sliding hip screw with or without an anti-rotation screw. Size, location and length of the screws are the most effective parameters in terms of structural performance of internal fixation implants, hence the optimal configuration of the screws is necessary to be investigated to guide the clinical practice. The aim of this study was comparing an inverted triangle screw configuration with different screw fixation placements.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo, Interdisciplinarne tehničke znanosti, Temeljne medicinske znanosti, Interdisciplinarne biotehničke znanosti, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)