Pregled bibliografske jedinice broj: 1142866
Comparison between two types of screw configuration methods in treating of Pauwels type III femoral neck fracture: A finite element analysis
Comparison between two types of screw configuration methods in treating of Pauwels type III femoral neck fracture: A finite element analysis // 41st SICOT Orthopaedic World Congress
Budimpešta, Mađarska, 2021. (poster, međunarodna recenzija, ostalo, znanstveni)
CROSBI ID: 1142866 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison between two types of screw
configuration methods in treating of Pauwels
type III femoral neck fracture: A finite
element analysis
Autori
Sabalić, Srećko ; Adamović, Petra ; Kalajžić, Lea ; Blažević, Dejan ; Kodvanj, Janoš
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, ostalo, znanstveni
Skup
41st SICOT Orthopaedic World Congress
Mjesto i datum
Budimpešta, Mađarska, 15.09.2021. - 18.09.2021
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
finite element analysis ; biomechanical stability ; inverted triangle ; femoral neck fracture ; Pauwels Type III
Sažetak
The new x-crossed configuration provides better biomechanical stability than the inverted triangle configuration. This shows not only that the number of postoperative complication could be significantly reduced, but also opportunity to form new studies and treating methods of femoral neck fractures.