Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1134818

Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study


Barišić Kutija, Marija; Kuzman, Tomislav; Kalauz, Miro; Jukić, Tomislav; Perić, Sanja; Jandroković, Sonja; Škegro, Ivan; Masnec, Sanja; Mrazovac Zimak, Danijela; Vukojević, Nenad
Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study // Acta clinica Croatica, 61 (2022), 2; 198-204 doi:10.20471/acc.2022.61.02.05 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1134818 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study

Autori
Barišić Kutija, Marija ; Kuzman, Tomislav ; Kalauz, Miro ; Jukić, Tomislav ; Perić, Sanja ; Jandroković, Sonja ; Škegro, Ivan ; Masnec, Sanja ; Mrazovac Zimak, Danijela ; Vukojević, Nenad

Izvornik
Acta clinica Croatica (0353-9466) 61 (2022), 2; 198-204

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Lens care compliance ; RGP lens

Sažetak
The aim was to estimate compliance rate among rigid gas permeable lens wearers (RGPLW) in lens system care, identify procedures in lens care process with poorest compliance levels, and assess concordance between participant reported practices and their subjectively perceived compliance. The study included outpatient RGPLW managed at Zagreb University Hospital Center in Zagreb, Croatia. They filled out a questionnaire that included demographic data, duration of lens wear, self-evaluation compliance grade, and 14 lens care procedures and wearing habits indicative of compliance. There were 50 patients (mean age 34.6 years, 68% female). Full compliance was found in a single patient. The mean number of non-compliant procedures was 5.48, with 32% of participants non-compliant in more than 50% of the compliance criteria. Critical procedures of the lens care process were infrequent lens case exchange (74%), using tap water for lens (70%), and improper case cleaning (68%). The mean lens case replacement time was 9.8 months (SD 6.76), with only 26% of patients replacing lens case at least once in 3 months. Excessive daily lens wear was associated with greater total number of non-compliant procedures (p<0.0008). RGPLW were aware of their inappropriate lens care only when achieved non-compliance in almost 50% of the procedures. In conclusion, lens wearers were not aware of their extremely low compliance rate in several aspects of lens and lens case maintenance. Study results indicated the key procedures the practitioners should focus on when evaluating subjective and objective compliance and reinforcing care and hygiene education of RGPLW.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb

Poveznice na cjeloviti tekst rada:

doi hrcak.srce.hr

Citiraj ovu publikaciju:

Barišić Kutija, Marija; Kuzman, Tomislav; Kalauz, Miro; Jukić, Tomislav; Perić, Sanja; Jandroković, Sonja; Škegro, Ivan; Masnec, Sanja; Mrazovac Zimak, Danijela; Vukojević, Nenad
Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study // Acta clinica Croatica, 61 (2022), 2; 198-204 doi:10.20471/acc.2022.61.02.05 (međunarodna recenzija, članak, znanstveni)
Barišić Kutija, M., Kuzman, T., Kalauz, M., Jukić, T., Perić, S., Jandroković, S., Škegro, I., Masnec, S., Mrazovac Zimak, D. & Vukojević, N. (2022) Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study. Acta clinica Croatica, 61 (2), 198-204 doi:10.20471/acc.2022.61.02.05.
@article{article, author = {Bari\v{s}i\'{c} Kutija, Marija and Kuzman, Tomislav and Kalauz, Miro and Juki\'{c}, Tomislav and Peri\'{c}, Sanja and Jandrokovi\'{c}, Sonja and \v{S}kegro, Ivan and Masnec, Sanja and Mrazovac Zimak, Danijela and Vukojevi\'{c}, Nenad}, year = {2022}, pages = {198-204}, DOI = {10.20471/acc.2022.61.02.05}, keywords = {Lens care compliance, RGP lens}, journal = {Acta clinica Croatica}, doi = {10.20471/acc.2022.61.02.05}, volume = {61}, number = {2}, issn = {0353-9466}, title = {Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study}, keyword = {Lens care compliance, RGP lens} }
@article{article, author = {Bari\v{s}i\'{c} Kutija, Marija and Kuzman, Tomislav and Kalauz, Miro and Juki\'{c}, Tomislav and Peri\'{c}, Sanja and Jandrokovi\'{c}, Sonja and \v{S}kegro, Ivan and Masnec, Sanja and Mrazovac Zimak, Danijela and Vukojevi\'{c}, Nenad}, year = {2022}, pages = {198-204}, DOI = {10.20471/acc.2022.61.02.05}, keywords = {Lens care compliance, RGP lens}, journal = {Acta clinica Croatica}, doi = {10.20471/acc.2022.61.02.05}, volume = {61}, number = {2}, issn = {0353-9466}, title = {Lens Care Compliance Rates and Perceptions among Rigid Gas Permeable Contact Lens Wearers – a Pilot Study}, keyword = {Lens care compliance, RGP lens} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font