Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1133188

Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals


(EURADOS WG12) O’Connor, Una; Carinou, Elefteria; Clairand, Isabelle; Ciraj-Bjelac, Olivera; De Montee, Fracesca; Domienik-Andrzejewska, Joanna; Ferrari, Paolo; Ginjaume, Merce; Hršak, Hrvoje; Hupe, Oliver et al.
Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals // Physica medica, 87 (2021), 131-135 doi:10.1016/j.ejmp.2021.05.015 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1133188 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals

Autori
O’Connor, Una ; Carinou, Elefteria ; Clairand, Isabelle ; Ciraj-Bjelac, Olivera ; De Montee, Fracesca ; Domienik-Andrzejewska, Joanna ; Ferrari, Paolo ; Ginjaume, Merce ; Hršak, Hrvoje ; Hupe, Oliver ; Knežević, Željka ; Sans Merce, Marta ; Sarmenton, Sandra ; Siiskonen, Teemu ; Vanhavere, Filip

Kolaboracija
EURADOS WG12

Izvornik
Physica medica (1120-1797) 87 (2021); 131-135

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Radiation ; Protection ; Dosememter ; Interventional

Sažetak
Occupational radiation doses from interventional procedures have the potential to be relatively high. The requirement to optimise these doses encourages the use of electronic or active personal dosimeters (APDs) which are now increasingly used in hospitals. They are typically used in tandem with a routine passive dosimetry monitoring programme, with APDs used for real-time readings, for training purposes and when new imaging technology is introduced. However, there are limitations when using APDs. A survey in hospitals to identify issues related to the use of APDs was recently completed, along with an extensive series of APD tests by the EURADOS Working Group 12 on Dosimetry for Medical Imaging. The aim of this review paper is to summarise the state of the art regarding the use of APDs. We also used the results of our survey and our tests to develop a set of recommendations for the use of APDs in the clinical interventional radiology/cardiology settings, and draw attention to some of the current challenges.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Interdisciplinarne prirodne znanosti, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb,
Klinički bolnički centar Zagreb

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org fulir.irb.hr

Citiraj ovu publikaciju:

(EURADOS WG12) O’Connor, Una; Carinou, Elefteria; Clairand, Isabelle; Ciraj-Bjelac, Olivera; De Montee, Fracesca; Domienik-Andrzejewska, Joanna; Ferrari, Paolo; Ginjaume, Merce; Hršak, Hrvoje; Hupe, Oliver et al.
Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals // Physica medica, 87 (2021), 131-135 doi:10.1016/j.ejmp.2021.05.015 (međunarodna recenzija, članak, znanstveni)
(EURADOS WG12) (EURADOS WG12) O’Connor, U., Carinou, E., Clairand, I., Ciraj-Bjelac, O., De Montee, F., Domienik-Andrzejewska, J., Ferrari, P., Ginjaume, M., Hršak, H. & Hupe, O. (2021) Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals. Physica medica, 87, 131-135 doi:10.1016/j.ejmp.2021.05.015.
@article{article, author = {O’Connor, Una and Carinou, Elefteria and Clairand, Isabelle and Ciraj-Bjelac, Olivera and De Montee, Fracesca and Domienik-Andrzejewska, Joanna and Ferrari, Paolo and Ginjaume, Merce and Hr\v{s}ak, Hrvoje and Hupe, Oliver and Kne\v{z}evi\'{c}, \v{Z}eljka and Sans Merce, Marta and Sarmenton, Sandra and Siiskonen, Teemu and Vanhavere, Filip}, year = {2021}, pages = {131-135}, DOI = {10.1016/j.ejmp.2021.05.015}, keywords = {Radiation, Protection, Dosememter, Interventional}, journal = {Physica medica}, doi = {10.1016/j.ejmp.2021.05.015}, volume = {87}, issn = {1120-1797}, title = {Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals}, keyword = {Radiation, Protection, Dosememter, Interventional} }
@article{article, author = {O’Connor, Una and Carinou, Elefteria and Clairand, Isabelle and Ciraj-Bjelac, Olivera and De Montee, Fracesca and Domienik-Andrzejewska, Joanna and Ferrari, Paolo and Ginjaume, Merce and Hr\v{s}ak, Hrvoje and Hupe, Oliver and Kne\v{z}evi\'{c}, \v{Z}eljka and Sans Merce, Marta and Sarmenton, Sandra and Siiskonen, Teemu and Vanhavere, Filip}, year = {2021}, pages = {131-135}, DOI = {10.1016/j.ejmp.2021.05.015}, keywords = {Radiation, Protection, Dosememter, Interventional}, journal = {Physica medica}, doi = {10.1016/j.ejmp.2021.05.015}, volume = {87}, issn = {1120-1797}, title = {Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals}, keyword = {Radiation, Protection, Dosememter, Interventional} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font