Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture


Bjelica, Roko; Čelebić, Asja; Filipovic-Zore, Irina; Milat, Ognjen; Peršić, Sanja; Kovačić, Ines
Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture // 30th Annual Congress of European College of Gerodontology / Anastassia Kossioni (ur.).
Atena, Grčka, 2020. str. 134-134 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 1110601 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture

Autori
Bjelica, Roko ; Čelebić, Asja ; Filipovic-Zore, Irina ; Milat, Ognjen ; Peršić, Sanja ; Kovačić, Ines

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
30th Annual Congress of European College of Gerodontology / Anastassia Kossioni - , 2020, 134-134

Skup
30th Annual Congress of European College of Gerodontology

Mjesto i datum
Atena, Grčka, 09.10.2020. - 10.10.2020

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
mini dental implants ; overdentures ; mucosa thickness ; peri-implants bone stress

Sažetak
Background and aim: Soft tissues overlying edentulous residual ridges are supposed to be the primary stress bearing area, affecting stability and denture movements under masticatory loads. Dental implants have been used to enhance removable denture retention and stability, especially in geriatric patients with thin residual ridges. The aim of this study was to evaluate influence of different thickness of mucosal tissues under different mandibular overdenture loadings on peri-implant stress and strains of four mini-implants (MDI). Methods: One model of the mandible with severely atrophied and thin residual ridge was 3D printed, based on a CBCT scan, using a material with similar mechanical properties as the bone. Four MDIs (2.0x10 mm) were inserted interforaminaly at approximate sites of teeth 34, 32, 42, and 44, parallel to each other. Strain gauges (SG) were placed at the cervical MDI sites, one SG buccally and another orally, altogether eight SGs were placed. Measurements were made with artificial mucosa (soft silicone) of 1.5, 3 and 4 mm thickness overlying posterior denture bearing area. Forces of 50N, 100N and 150N were applied on the overdenture in the first molar region bilaterally and unilaterally. Each measurement was repeated three times. Results: A combination of compressive and tensile deformations were recorded with SGs and the computer software (Kyowa DCS-100A Dynamic Data Acquisition Software) showing the maximum values for each of the applied forces. With an increase of the applied loads, an increase in deformations was recorded (p < 0.001). With increasing the artificial mucosa thickness from 1.5 to 3 mm peri-implant deformations increased, but with the 4 mm thick mucosa stresses further increased in some SG positions, but in another turned to negative (p < 0.001), and the overdenture sometimes lost retention and lifted up. Multivariate analysis revealed significant influence of tissue thickness, loads and their combination (p<0.001). Conclusions: Within the limitations of this study it was concluded that thickness of the mucosa had significant effect on strain and stresses of cervical peri-implant bone. Increased mucosal thickness and loads may cause adverse effects to peri-implant bone of MDIs.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina



POVEZANOST RADA


Projekti:
IP-2014-09-1218 - Definiranje mogućnosti uporabe mini dentalnih implantata (MDI) i njihovi rezultati u in vitro i u kliničkim prospektivnim istraživanjima (Mini implantati/ MDI) (HRZZ - 2014-09) ( CroRIS)
MZOS-035-0352843-2844 - Veza strukturnih i fizikalnih svojstava materijala kontrolirane dimenzionalnosti (Milat, Ognjen, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb

Citiraj ovu publikaciju:

Bjelica, Roko; Čelebić, Asja; Filipovic-Zore, Irina; Milat, Ognjen; Peršić, Sanja; Kovačić, Ines
Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture // 30th Annual Congress of European College of Gerodontology / Anastassia Kossioni (ur.).
Atena, Grčka, 2020. str. 134-134 (poster, međunarodna recenzija, sažetak, znanstveni)
Bjelica, R., Čelebić, A., Filipovic-Zore, I., Milat, O., Peršić, S. & Kovačić, I. (2020) Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture. U: Anastassia Kossioni (ur.)30th Annual Congress of European College of Gerodontology.
@article{article, author = {Bjelica, Roko and \v{C}elebi\'{c}, Asja and Filipovic-Zore, Irina and Milat, Ognjen and Per\v{s}i\'{c}, Sanja and Kova\v{c}i\'{c}, Ines}, year = {2020}, pages = {134-134}, keywords = {mini dental implants, overdentures, mucosa thickness, peri-implants bone stress}, title = {Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture}, keyword = {mini dental implants, overdentures, mucosa thickness, peri-implants bone stress}, publisherplace = {Atena, Gr\v{c}ka} }
@article{article, author = {Bjelica, Roko and \v{C}elebi\'{c}, Asja and Filipovic-Zore, Irina and Milat, Ognjen and Per\v{s}i\'{c}, Sanja and Kova\v{c}i\'{c}, Ines}, year = {2020}, pages = {134-134}, keywords = {mini dental implants, overdentures, mucosa thickness, peri-implants bone stress}, title = {Effect of different thickness of soft tissues of the posterior denture bearing area on peri-implant stress and strains in four mini-implant retained mandibular overdenture}, keyword = {mini dental implants, overdentures, mucosa thickness, peri-implants bone stress}, publisherplace = {Atena, Gr\v{c}ka} }




Contrast
Increase Font
Decrease Font
Dyslexic Font