Pregled bibliografske jedinice broj: 1108631
Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experience
Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experience // Journal of Cardiovascular Electrophysiology, 32 (2021), 3; 580-587 doi:10.1111/jce.14915 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1108631 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of procedural efficacy and
biophysical parameters between two competing
cryoballoon technologies for pulmonary vein
isolation: Insights from an initial multicenter
experience
Autori
Yap, Sing‐Chien ; Anic, Ante ; Breskovic, Toni ; Haas, Annika ; Bhagwandien, Rohit E. ; Jurisic, Zrinka ; Szili‐Torok, Tamas ; Luik, Armin
Izvornik
Journal of Cardiovascular Electrophysiology (1045-3873) 32
(2021), 3;
580-587
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
atrial fibrillation ; catheter ablation ; cryoablation ; cryoballoon ; pulmonary vein isolation
Sažetak
Introduction: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA- Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems. Methods: One hundred and ten consecutive patients who underwent first-time cryoballoon ablation (POLARx: n = 57 ; AFA-Pro: n = 53) were included in this prospective cohort study. Results: Acute isolation was achieved in 99.8% of all pulmonary veins (POLARx: 99.5% vs. AFA- Pro: 100%, p = 1.00). Total procedure time (81 vs. 67 min, p < .001) and balloon in body time (51 vs. 35 min, p < .001) were longer with POLARx. After a learning curve, these times were similar. Cryoablation with POLARx was associated with shorter time to balloon temperature -30°C (27 vs. 31 s, p < .001) and -40°C (32 vs. 54 s, p < .001), lower balloon nadir temperature (-55°C vs. -47°C, p < .001), and longer thawing time till 0°C (16 vs. 9 s, p < .001). There were no differences in time-to- isolation (TTI ; POLARx: 45 s vs. AFA-Pro 43 s, p = .441), however, POLARx was associated with a lower balloon temperature at TTI (-46°C vs. -37°C, p < .001). Factors associated with acute isolation differed between groups. The incidence of phrenic nerve palsy was comparable (POLARx: 3.5% vs. AFA- Pro: 3.7%). Conclusion: The novel cryoballoon is comparable to AFA-Pro and requires only a short learning curve to get used to the slightly different handling. It was associated with faster cooling rates and lower balloon temperatures but TTI was similar to AFA-Pro.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
KBC Split,
Medicinski fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE