Pregled bibliografske jedinice broj: 1107259
Comparison of apical irrigant solution extrusion among conventional and laser- activated endodontic irrigation
Comparison of apical irrigant solution extrusion among conventional and laser- activated endodontic irrigation // Lasers in Medical Science, 35 (2020), 1; 205-211 doi:10.1007/s10103-019-02846-w (međunarodna recenzija, članak, ostalo)
CROSBI ID: 1107259 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of apical irrigant solution
extrusion among conventional and laser-
activated endodontic irrigation
Autori
Vidas, Jelena ; Snjaric, Damir ; Braut, Alen ; Carija, Zoran ; Persic Bukmir, Romana ; De Moor, Roeland J. G. ; Brekalo Prso, Ivana
Izvornik
Lasers in Medical Science (0268-8921) 35
(2020), 1;
205-211
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, ostalo
Ključne riječi
Endodontics ; Er YAG laser ; Laser-activated irrigation ; Root canal irrigants ; Sodium hypochlorite
Sažetak
The aim of this study was to determine the amount of extruded endodontic irrigant among needle-syringe irrigation (NSI) and laser- activated irrigation (LAI) regimens. Twenty extracted maxillary central incisors were prepared utilizing GT professional rotary files (size 40, taper 0.06). Irrigation was performed with two 27 G irrigation needles (notched open ended (ON) and single side vented (SV)) each at two different irrigant volumetric flow rates (VFR)-0.05 ml/s (3 ml/min) and 0.10 ml/s (6 ml/min). LAI was performed with Er:YAG (erbium- doped yttrium aluminum garnet) using different fiber types (X-Pulse-14/400 cylindrical tip, Preciso- 14/300 flat cylindrical tip, PIPS- 14/400 quartz tapered tip). The Er:YAG laser with a wavelength of 2940 nm (Lightwalker AT, Fotona, Ljubljana, Slovenia) was used according to the following protocol: 10 mJ per pulse, 15 Hz, pulse duration 50 μs. Irrigation time was 60 s for all protocols. Precision syringe pump (PSP) maintained constant irrigant volumetric flow rate. Apically extruded irrigant was collected and net weighed for each protocol (N = 10). Data were analyzed by t tests and Kruskal-Wallis. All LAI regimens had statistically significant lower irrigant extrusion compared with NSI except for the SV 27 G needle used with 0.05 ml/s VFR when compared with the Preciso fiber tip (p = 0, 230). The largest amount of extruded irrigant was with the ON 27 G needle at the 0.10 ml/s VFR, while the smallest was after LAI with PIPS fiber tip. The lower quantity of apically extruded irrigant during LAI (X-Pulse and PIPS) points out a safer endodontic irrigation method compared with conventional irrigations.
Izvorni jezik
Engleski
Znanstvena područja
Dentalna medicina
POVEZANOST RADA
Ustanove:
Fakultet dentalne medicine, Rijeka
Profili:
Ivana Brekalo Pršo
(autor)
Alen Braut
(autor)
Damir Šnjarić
(autor)
Romana Peršić Bukmir
(autor)
Zoran Čarija
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE