Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1106335

His-bundle lead implantation program: a 2-year single-centre experience


Pašara, Vedran; Prepolec, Ivan; Matasić, Richard; Pezo- Nikolić, Borka; Krpan, Miroslav; Puljević, Mislav; Puljević, Davor; Lovrić Benčić, Martina; Miličić, Davor; Velagić, Vedran
His-bundle lead implantation program: a 2-year single-centre experience // Cardiologia Croatica, 16 (2021), 1-2
online, 2021. str. 63-63 doi:10.15836/ccar2021.63 (poster, domaća recenzija, sažetak, stručni)


CROSBI ID: 1106335 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
His-bundle lead implantation program: a 2-year single-centre experience
(His-bundle lead implantation program: a 2-year single-centre experience)

Autori
Pašara, Vedran ; Prepolec, Ivan ; Matasić, Richard ; Pezo- Nikolić, Borka ; Krpan, Miroslav ; Puljević, Mislav ; Puljević, Davor ; Lovrić Benčić, Martina ; Miličić, Davor ; Velagić, Vedran

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Cardiologia Croatica, 16 (2021), 1-2 / - , 2021, 63-63

Skup
13. kongres Hrvatskoga kardiološkog društva s međunarodnim sudjelovanjem

Mjesto i datum
Online, 10.12.2020. - 24.01.2021

Vrsta sudjelovanja
Poster

Vrsta recenzije
Domaća recenzija

Ključne riječi
his bundle pacing

Sažetak
His bundle pacing activates the ventricles physiologically by direct stimulation of the His- Purkinje cardiac conduction system.1 It was first described in the 1970s, first studies were reported in the early 2000s followed by technological advances that led to its widespread uptake and growing evidence base.1, 2 This retrospective study aimed to evaluate His-bundle lead implantation program in our centre. A total of 116 consecutive patients (63.8% male, 65.4 ± 13.6 years) who underwent His- bundle lead implantation in our centre from November 2018 until November 2020 were analyzed. Among these patients, over two-thirds (69.8%) had arterial hypertension, 43.1% had dyslipidemia and 29.3% had diabetes. Nearly half of patients (49.1%) had chronic heart failure, 26.7% had coronary artery disease and 8.6% had prior myocardial infarction. 40.5% of patients had atrial fibrillation. His-bundle lead implantation was achieved in 105 (90.5 %) of all patients, while the rest of the procedures were aborted and ended with right ventricle lead placement. Ten (8.6%) patients had postprocedural complications, six of which were resolved without lead extraction. Only one patient had a device-associated infection. With this analysis, we showed that the results of our His- bundle lead implantation program, regarding success and complication rates, are similar to available literature data.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb

Poveznice na cjeloviti tekst rada:

doi hrcak.srce.hr

Citiraj ovu publikaciju:

Pašara, Vedran; Prepolec, Ivan; Matasić, Richard; Pezo- Nikolić, Borka; Krpan, Miroslav; Puljević, Mislav; Puljević, Davor; Lovrić Benčić, Martina; Miličić, Davor; Velagić, Vedran
His-bundle lead implantation program: a 2-year single-centre experience // Cardiologia Croatica, 16 (2021), 1-2
online, 2021. str. 63-63 doi:10.15836/ccar2021.63 (poster, domaća recenzija, sažetak, stručni)
Pašara, V., Prepolec, I., Matasić, R., Pezo- Nikolić, B., Krpan, M., Puljević, M., Puljević, D., Lovrić Benčić, M., Miličić, D. & Velagić, V. (2021) His-bundle lead implantation program: a 2-year single-centre experience. U: Cardiologia Croatica, 16 (2021), 1-2 doi:10.15836/ccar2021.63.
@article{article, author = {Pa\v{s}ara, Vedran and Prepolec, Ivan and Matasi\'{c}, Richard and Pezo- Nikoli\'{c}, Borka and Krpan, Miroslav and Puljevi\'{c}, Mislav and Puljevi\'{c}, Davor and Lovri\'{c} Ben\v{c}i\'{c}, Martina and Mili\v{c}i\'{c}, Davor and Velagi\'{c}, Vedran}, year = {2021}, pages = {63-63}, DOI = {10.15836/ccar2021.63}, keywords = {his bundle pacing}, doi = {10.15836/ccar2021.63}, title = {His-bundle lead implantation program: a 2-year single-centre experience}, keyword = {his bundle pacing}, publisherplace = {online} }
@article{article, author = {Pa\v{s}ara, Vedran and Prepolec, Ivan and Matasi\'{c}, Richard and Pezo- Nikoli\'{c}, Borka and Krpan, Miroslav and Puljevi\'{c}, Mislav and Puljevi\'{c}, Davor and Lovri\'{c} Ben\v{c}i\'{c}, Martina and Mili\v{c}i\'{c}, Davor and Velagi\'{c}, Vedran}, year = {2021}, pages = {63-63}, DOI = {10.15836/ccar2021.63}, keywords = {his bundle pacing}, doi = {10.15836/ccar2021.63}, title = {His-bundle lead implantation program: a 2-year single-centre experience}, keyword = {his bundle pacing}, publisherplace = {online} }

Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font