Pregled bibliografske jedinice broj: 1103756
Reliability of the Measurement Method in Determining the Mass Concentration of Hardwood Dust
Reliability of the Measurement Method in Determining the Mass Concentration of Hardwood Dust // BioResources, 16 (2021), 1; 643-654 doi:10.15376/biores.16.1.643-654 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1103756 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Reliability of the Measurement Method in
Determining the Mass Concentration of Hardwood
Dust
Autori
Čavlović, Anka Ozana ; Bešlić, Ivan ; Zgorelec, Željka ; Ožegović Josip
Izvornik
BioResources (1930-2126) 16
(2021), 1;
643-654
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Wood dust ; Inhalable fraction ; Minimal sampling time ; Limit of detection ; Limit of quantification
Sažetak
The reliability of the measurement method in determining the mass concentration of wood dust relates to the sampling time for the detection of wood particles in the ambient air of woodworking places. The aim of this study was to calculate the mass Limit of detection (LOD) and Limit of quantification (LOQ) and the minimal sampling time (tLOD and tLOQ) for determination and quantification of samples, based on the hardwood dust mass concentration at various woodworking places in the sawmills, floor production factories, and carpentries. Determination of the mass concentration of respirable, inhalable, and total hardwood dust from ambient air was performed using personal sampling pumps and three types of filter holders: respirable dust cyclone, Institute of Occupational Medicine IOM inhalable dust sampler, and total dust open-faced filter holder. The average limit of detection amounts to 0.052, 0.083, and 0.167 mg for respirable, inhalable, and total hardwood dust, respectively. The minimal detection sampling time for collecting all observed types of dust fractions ranged between 1.12 h and 1.72 h. The minimal quantification time for all collected hardwood dust samples ranged from 3.75 h to 5.51 h. Pearson's correlation test showed that the reliability of the measurements was affected more by the dustiness of the workspace than the real sampling time.
Izvorni jezik
Engleski
Znanstvena područja
Javno zdravstvo i zdravstvena zaštita, Šumarstvo, Drvna tehnologija
POVEZANOST RADA
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb,
Fakultet šumarstva i drvne tehnologije,
Agronomski fakultet, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus