Pregled bibliografske jedinice broj: 1086070
Functional and magnetic resonance imaging outcome after polyurethane meniscal scaffold implantation following partial meniscectomy
Functional and magnetic resonance imaging outcome after polyurethane meniscal scaffold implantation following partial meniscectomy // International orthopaedics (SICOT), 45 (2021), 4; 971-975 doi:10.1007/s00264-020-04844-y (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1086070 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Functional and magnetic resonance imaging
outcome after polyurethane meniscal scaffold
implantation following partial meniscectomy
Autori
Hašpl, Miroslav ; Tršek, Denis ; Lovrić, Dražen ; Strahonja , Borna ; Matoković, Damir
Izvornik
International orthopaedics (SICOT) (0341-2695) 45
(2021), 4;
971-975
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Knee ; Meniscectomy ; Transplantation ; Meniscal scaffold
Sažetak
Purpose Prevention of the knee osteoarthritis following meniscectomy is implantation of an allotransplant or an artificial meniscus. We present retrospective study of our early results of the treatment using polyurethane meniscal scaffold. Methods From 2016 to 2020, we implanted nine polyurethane scaffolds (Actifit) after partial meniscectomy, five males and four females, age 36 (16–47), BMI 26.7 (17.2–35.9) kg/m2. Functional status, activity, pain, and MRI were assessed. Results FU 20.8 (6–48.5) months, 35.2 (0–68) months from the meniscectomy to the implantation. The average implant length was 46.1 (35–60) mm, average number of sutures was 7.6 (5–10). Lysholm score before surgery was 61.7 (49–85), after the surgery 86.4 (62–95) with p 0.0045, Tegner activity score before meniscectomy was 5.8 (4–7), after 3.8 (2–5), and after the scaffold implantation 4.6 (3–7) with p 0.0488. Before surgery, VAS score was 3.1 (2–4), and after 7.7 (5–9) with p 0.0042. Pursuant to the Genovese classification, the last follow-up MRI showed a type 2 meniscal morphology in four cases and a type 3 in five cases. Seven patients had type 1 and two had type 2 signal intensity. On average, the absolute extrusion of a transplanted meniscus was 3.67 mm, and the relative extrusion was 0.58 mm. Extrusion progress was not detected. Conclusion Significantly improved knee functionality, increased level of physical activity, and reduced pain. MRI analysis revealed the meniscal transplant morphology and volume loss, as well as its extrusion without progression.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Osijek,
Opća županijska bolnica Požega
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE