Pregled bibliografske jedinice broj: 1080135
Mikročip kapilarna elektroforetska analiza β-alanina i L-histidina s C4D detektorom
Mikročip kapilarna elektroforetska analiza β-alanina i L-histidina s C4D detektorom // Knjiga sažetaka 18. međunarodnog znanstveno- stručnog skupa: Ružičkini dani "Danas znanost - sutra industrija" / Jukić, Ante (ur.).
Zagreb : Osijek, 2020. str. 35-35 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 1080135 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Mikročip kapilarna elektroforetska
analiza β-alanina i L-histidina s
C4D detektorom
(Microchip Capillary Electrophoretic
Analysis of β-Alanine and L-histidine with
C4D Detector)
Autori
Jakić, Marija ; Sakač, Nikola ; Matasović, Brunislav ; Jozanović, Marija
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Knjiga sažetaka 18. međunarodnog znanstveno- stručnog skupa: Ružičkini dani "Danas znanost - sutra industrija"
/ Jukić, Ante - Zagreb : Osijek, 2020, 35-35
Skup
18. međunarodni znanstveno-stručni skup Ružičkini dani "Danas znanost - sutra industrija"
Mjesto i datum
Vukovar, Hrvatska, 16.09.2020. - 18.09.2020
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
amino acids ; β-alanine ; C4D detector ; L-histidine ; microchip capillary electrophoresis
Sažetak
β-Alanine and L-histidine supplementation results in elevated intramuscular carnosine content, enhancing human physical performance [1]. Thus, aforementioned amino acids are important constituent of animal feeds used in production of functional food with elevated levels of carnosine and also in various preworkout supplements. Therefore, it is necessary to develop fast and reliable analytical methods for the detection of these amino acids. Microchip capillary electrophoresis (MCE) using capacitively coupled contactless conductivity detector (C4D) in various acidic electrophoretic buffers provides high resolution and short separation time for quantitative determination of β-alanine and L-histidine. The influence of the injection and separation parameters on the separation ability was investigated. The electrophoretic buffer composition were thoroughly studied in order to optimize the separation. The linear response region for each particular amino acid investigated, both single and in a mixture, was determined using linear regression. Detection limits for β-alanine and L-histidine were below 1 mg mL-1.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Interdisciplinarne prirodne znanosti, Nutricionizam
POVEZANOST RADA
Projekti:
grant #KK.01.1.1.01.0010
Ustanove:
Geotehnički fakultet, Varaždin,
Sveučilište u Osijeku - Odjel za kemiju