Pregled bibliografske jedinice broj: 1077336
Fabric phase sorptive extraction combined with high-performance liquid chromatography - photodiode array analysis for the determination of seven parabens in human breast tissues: application to cancerous and noncancerous samples
Fabric phase sorptive extraction combined with high-performance liquid chromatography - photodiode array analysis for the determination of seven parabens in human breast tissues: application to cancerous and noncancerous samples // Journal of chromatography. A, 1630 (2020), 461530, 11 doi:10.1016/j.chroma.2020.461530 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1077336 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Fabric phase sorptive extraction combined with high-performance liquid chromatography - photodiode array analysis for the determination of
seven parabens in human breast tissues: application to cancerous and noncancerous
samples
Autori
Alampanos, Vasileios ; Kabir, Abuzar ; Furton, Kenneth ; Roje, Željka ; Vinković Vrček, Ivana ; Samanidou, Victoria
Izvornik
Journal of chromatography. A (0021-9673) 1630
(2020);
461530, 11
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Fabric phase sorptive extraction (FPSE) ; parabens ; breast tissue ; sample preparation ; bioanalysis
Sažetak
An improved pretreatment approach of human breast tissue is demonstrated for subsequent analysis of seven parabens including methyl paraben (MPB), ethyl paraben (EPB), propyl paraben (PPB), butyl paraben (BPB), isopropyl paraben (iPPB), isobutyl paraben (iBPB), and benzyl paraben (BzPB). Specifically, a well-designed homogenization procedure, conjugated with an optimized fabric phase sorptive extraction (FPSE) protocol, resulted in a carefully outlined sample preparation process as part of a green, simple, sensitive, economical and fast HPLC-PDA analytical method in agreement with Green Analytical Chemistry (GAC) demands. Among all tested FPSE membranes, the highest extraction efficiency was achieved by employing sol-gel poly(tetrahydrofuran) (sol-gel PTHF) coating on 100% cotton cellulose fabric that represents a medium polarity microextraction device, which combined the advanced material characteristics of sol-gel sorbent and the rich surface chemistry of an inherent porous cellulose fabric substrate. The chromatographic separation was accomplished with a Spherisorb C18 column and an isocratic mobile phase consisted of ammonium acetate and acetonitrile at a flow rate of 1.4 mL/min. The total analysis time was 13.6 min. The analytical adequacy of the composite sample preparation and chromatographic separation method was strongly evidenced by its successful application in the bioanalysis of real cancerous and non-cancerous tissue samples originated from different subregions of human breast including axila, the upper left and the right quadrant. In all samples, at least one paraben was detected, while 35% of the samples were tested positive for all seven target parabens. Moreover, concentration levels of parabens in cancerous tissues were unambiguously higher than in healthy tissues. The obtained results underlined bioaccumulation potential of parabens in human breast tissue as a consequence of constant low-dose exposure of humans, despite the statutory concentration limits. The developed methodology has demonstrated to be suitable and efficient for future epidemiological and toxicological studies.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Interdisciplinarne prirodne znanosti, Kliničke medicinske znanosti, Farmacija
POVEZANOST RADA
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb,
Klinička bolnica "Dubrava"
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE