3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology


Surić Mihić, Marija; Pavelić, Luka; Vojnić Kortmiš, Maja; Šiško, Jerko; Maltar-Strmečki, Nadica; Prlić, Ivica
3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology // Radiation measurements, 135 (2020), 106385, 6 doi:10.1016/j.radmeas.2020.106385 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1063490 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology

Autori
Surić Mihić, Marija ; Pavelić, Luka ; Vojnić Kortmiš, Maja ; Šiško, Jerko ; Maltar-Strmečki, Nadica ; Prlić, Ivica

Izvornik
Radiation measurements (1350-4487) 135 (2020); 106385, 6

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Eye lens dosimetry ; Hp(3) ; Li2B4O7 ; Eye lens dosemeter holder ; Personal dosimetry

Sažetak
Mandatory eye lens monitoring for exposed workers who are liable to receive an equivalent dose to the lens of the eye higher than 15 mSv in one year, required by the new European Basic Safety Standard 2013/59 and the recommendation given by the International Commission on Radiological Protection to lower the annual dose limit for the lens of the eye to 20 mSv, have put dosimetry services using Panasonic dosemeters in a difficult position. There are no commercially available eye lens dosemeter holders to fit Panasonic TLD pellets. Therefore, we designed and 3D printed inexpensive, splash proof, reusable and comfortable holders to fit a Panasonic nLi2nB4O7:Cu pellet. The eye lens dosemeter consists of an acrylonitrile butadiene styrene (ABS) plastic holder with a slot for a TLD pellet. The slot with the TLD pellet is covered by a heat-shrink tube and shortly heated with hot air to shrink wrap. Results of combined energy/angular response measurements, for all photon radiation qualities used, relative to N- 100 at 0° as the reference energy, were within IEC 62387:2012 limits. Additionally, electron spin resonance spectroscopy was used to test the effect of irradiation to the degradation properties of the plastic ABS holder. The dosemeter is to be worn fixed to a headband, close to the eye, on the left side of the head or in the middle of the forehead.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Interdisciplinarne prirodne znanosti, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb,
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org

Citiraj ovu publikaciju:

Surić Mihić, Marija; Pavelić, Luka; Vojnić Kortmiš, Maja; Šiško, Jerko; Maltar-Strmečki, Nadica; Prlić, Ivica
3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology // Radiation measurements, 135 (2020), 106385, 6 doi:10.1016/j.radmeas.2020.106385 (međunarodna recenzija, članak, znanstveni)
Surić Mihić, M., Pavelić, L., Vojnić Kortmiš, M., Šiško, J., Maltar-Strmečki, N. & Prlić, I. (2020) 3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology. Radiation measurements, 135, 106385, 6 doi:10.1016/j.radmeas.2020.106385.
@article{article, author = {Suri\'{c} Mihi\'{c}, Marija and Paveli\'{c}, Luka and Vojni\'{c} Kortmi\v{s}, Maja and \v{S}i\v{s}ko, Jerko and Maltar-Strme\v{c}ki, Nadica and Prli\'{c}, Ivica}, year = {2020}, pages = {6}, DOI = {10.1016/j.radmeas.2020.106385}, chapter = {106385}, keywords = {Eye lens dosimetry, Hp(3), Li2B4O7, Eye lens dosemeter holder, Personal dosimetry}, journal = {Radiation measurements}, doi = {10.1016/j.radmeas.2020.106385}, volume = {135}, issn = {1350-4487}, title = {3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology}, keyword = {Eye lens dosimetry, Hp(3), Li2B4O7, Eye lens dosemeter holder, Personal dosimetry}, chapternumber = {106385} }
@article{article, author = {Suri\'{c} Mihi\'{c}, Marija and Paveli\'{c}, Luka and Vojni\'{c} Kortmi\v{s}, Maja and \v{S}i\v{s}ko, Jerko and Maltar-Strme\v{c}ki, Nadica and Prli\'{c}, Ivica}, year = {2020}, pages = {6}, DOI = {10.1016/j.radmeas.2020.106385}, chapter = {106385}, keywords = {Eye lens dosimetry, Hp(3), Li2B4O7, Eye lens dosemeter holder, Personal dosimetry}, journal = {Radiation measurements}, doi = {10.1016/j.radmeas.2020.106385}, volume = {135}, issn = {1350-4487}, title = {3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology}, keyword = {Eye lens dosimetry, Hp(3), Li2B4O7, Eye lens dosemeter holder, Personal dosimetry}, chapternumber = {106385} }