Non‐conformities in tissue typing laboratory: Croatian experience


Katalinic, N.; Starcevic, A.; Mavrinac, M.; Vuk, T.; Balen, S.
Non‐conformities in tissue typing laboratory: Croatian experience // Transfusion medicine, 29 (2019), 442-447 doi:10.1111/tme.12642 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1049481 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Non‐conformities in tissue typing laboratory: Croatian experience

Autori
Katalinic, N. ; Starcevic, A. ; Mavrinac, M. ; Vuk, T. ; Balen, S.

Izvornik
Transfusion medicine (0958-7578) 29 (2019); 442-447

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
accreditation ; histocompatibility testing ; HLA ; quality assurance ; quality control

Sažetak
Objectives Our study aimed to determine the frequency and type of non-conformities that occurred in the tissue typing laboratory (TTL), Rijeka, Croatia, in order to evaluate the quality of testing and compliance with the requirements of the quality management system (QMS). Background The QMS in a TTL should lead to improvements in the accuracy and timeliness of results. One of its essential elements is non-conformity management. Methods A retrospective analysis of non-conformities recorded in the TTL Rijeka from 2006 to 2017 revealed the overall frequency of 0 center dot 43%. Classification was performed according to the examination phase, employee characteristics, relation to the field of work, part of laboratory and priority of testing. Results The most reported non-conformities occurred during the examination phase (54 center dot 0%), followed by the pre- and post- examination phase (31 center dot 2 and 14 center dot 8%, respectively). Inadequate competency and less experience were associated with the number of reported non-conformities while no difference was observed in relation to the profession or position in the laboratory. Non-conformities were equally distributed between organ transplantation and HLA- associated disease diagnostic processes, mostly referring to the entire laboratory work. Conclusion Intensifying training and education, implementation of information technology into laboratory processes, more rigorous error detection and reporting are fundamental steps in improving quality of laboratory services.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Klinički bolnički centar Rijeka,
Fakultet za dentalnu medicinu i zdravstvo, Osijek

Profili:

Avatar Url Sanja Balen (autor)

Avatar Url Martina Mavrinac (autor)

Avatar Url Nataša Katalinić (autor)

Poveznice na cjeloviti tekst rada:

doi doi.org

Citiraj ovu publikaciju:

Katalinic, N.; Starcevic, A.; Mavrinac, M.; Vuk, T.; Balen, S.
Non‐conformities in tissue typing laboratory: Croatian experience // Transfusion medicine, 29 (2019), 442-447 doi:10.1111/tme.12642 (međunarodna recenzija, članak, znanstveni)
Katalinic, N., Starcevic, A., Mavrinac, M., Vuk, T. & Balen, S. (2019) Non‐conformities in tissue typing laboratory: Croatian experience. Transfusion medicine, 29, 442-447 doi:10.1111/tme.12642.
@article{article, author = {Katalinic, N. and Starcevic, A. and Mavrinac, M. and Vuk, T. and Balen, S.}, year = {2019}, pages = {442-447}, DOI = {10.1111/tme.12642}, keywords = {accreditation, histocompatibility testing, HLA, quality assurance, quality control}, journal = {Transfusion medicine}, doi = {10.1111/tme.12642}, volume = {29}, issn = {0958-7578}, title = {Non‐conformities in tissue typing laboratory: Croatian experience}, keyword = {accreditation, histocompatibility testing, HLA, quality assurance, quality control} }
@article{article, author = {Katalinic, N. and Starcevic, A. and Mavrinac, M. and Vuk, T. and Balen, S.}, year = {2019}, pages = {442-447}, DOI = {10.1111/tme.12642}, keywords = {accreditation, histocompatibility testing, HLA, quality assurance, quality control}, journal = {Transfusion medicine}, doi = {10.1111/tme.12642}, volume = {29}, issn = {0958-7578}, title = {Non‐conformities in tissue typing laboratory: Croatian experience}, keyword = {accreditation, histocompatibility testing, HLA, quality assurance, quality control} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font