Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses


Rastogi, Shivam; Singh, Ramandeep; Borse, Riddhi; Valkovic Zujic, Petra; Segota, Doris; Diklic, Ana; Jurkovic, Slaven; Ali, Antar; Kharita, Mohammed Hassan; Al-Naemi, Huda M et al.
Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses // Canadian association of radiologists journal- journal de l association canadienne des radiologistes, 71 (2020), 1; 6, 7 doi:10.1177/0846537119888390 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1045494 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses

Autori
Rastogi, Shivam ; Singh, Ramandeep ; Borse, Riddhi ; Valkovic Zujic, Petra ; Segota, Doris ; Diklic, Ana ; Jurkovic, Slaven ; Ali, Antar ; Kharita, Mohammed Hassan ; Al-Naemi, Huda M ; Alkalbani, Jokha ; Al-Rasbi, Amaal ; Gershan, Vesna ; Galic, Stipe ; Yusuf, Mohammad ; Avramova-Cholakova, Simona ; Zulkipli, Ili Majidah Binti Hj ; Shein, Nilar ; Teferi, Seife ; Rehani, Madan ; Vassileva, Jenia ; Kalra, Mannudeep

Izvornik
Canadian association of radiologists journal- journal de l association canadienne des radiologistes (0846-5371) 71 (2020), 1; 6, 7

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
CT chest ; CT abdomen–pelvis ; multiphase scanning ; radiation dose ; justification

Sažetak
Purpose: To assess the frequency, appropriateness, and radiation doses associated with multiphase computed tomography (CT) protocols for routine chest and abdomen–pelvis examinations in 18 countries. Materials and Methods: In collaboration with the International Atomic Energy Agency, multi- institutional data on clinical indications, number of scan phases, scan parameters, and radiation dose descriptors (CT dose–index volume ; dose–length product [DLP]) were collected for routine chest (n ¼ 1706 patients) and abdomen–pelvis (n ¼ 426 patients) CT from 18 institutions in Asia, Africa, and Europe. Two radiologists scored the need for each phase based on clinical indications (1 ¼ not indicated, 2 ¼ probably indicated, 3 ¼ indicated). We surveyed 11 institutions for their practice regarding single-phase and multiphase CT examinations. Data were analyzed with the Student t test. Results: Most institutions use multiphase protocols for routine chest (10/18 institutions) and routine abdomen–pelvis (10/11 institutions that supplied data for abdomen–pelvis) CT examinations. Most institutions (10/11) do not modify scan parameters between different scan phases. Respective total DLP for 1-, 2-, and 3- phase routine chest CT was 272, 518, and 820 mGy_cm, respectively. Corresponding values for 1- to 5-phase routine abdomen–pelvis CT were 400, 726, 1218, 1214, and 1458 mGy cm, respectively. For multiphase CT protocols, there were no differences in scan parameters and radiation doses between different phases for either chest or abdomen–pelvis CT (P ¼ 0.40 0.99). Multiphase CT examinations were unnecessary in 100% of routine chest CT and in 63% of routine abdomen– pelvis CT examinations. Conclusions: Multiphase scan protocols for the routine chest and abdomen– pelvis CT examinations are unnecessary, and their use increases radiation dose.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Temeljne medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Klinički bolnički centar Rijeka

Poveznice na cjeloviti tekst rada:

doi journals.sagepub.com

Citiraj ovu publikaciju:

Rastogi, Shivam; Singh, Ramandeep; Borse, Riddhi; Valkovic Zujic, Petra; Segota, Doris; Diklic, Ana; Jurkovic, Slaven; Ali, Antar; Kharita, Mohammed Hassan; Al-Naemi, Huda M et al.
Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses // Canadian association of radiologists journal- journal de l association canadienne des radiologistes, 71 (2020), 1; 6, 7 doi:10.1177/0846537119888390 (međunarodna recenzija, članak, znanstveni)
Rastogi, S., Singh, R., Borse, R., Valkovic Zujic, P., Segota, D., Diklic, A., Jurkovic, S., Ali, A., Kharita, M. & Al-Naemi, H. (2020) Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses. Canadian association of radiologists journal- journal de l association canadienne des radiologistes, 71 (1), 6, 7 doi:10.1177/0846537119888390.
@article{article, author = {Rastogi, Shivam and Singh, Ramandeep and Borse, Riddhi and Valkovic Zujic, Petra and Segota, Doris and Diklic, Ana and Jurkovic, Slaven and Ali, Antar and Kharita, Mohammed Hassan and Al-Naemi, Huda M and Alkalbani, Jokha and Al-Rasbi, Amaal and Gershan, Vesna and Galic, Stipe and Yusuf, Mohammad and Avramova-Cholakova, Simona and Zulkipli, Ili Majidah Binti Hj and Shein, Nilar and Teferi, Seife and Rehani, Madan and Vassileva, Jenia and Kalra, Mannudeep}, year = {2020}, pages = {7}, DOI = {10.1177/0846537119888390}, chapter = {6}, keywords = {CT chest, CT abdomen–pelvis, multiphase scanning, radiation dose, justification}, journal = {Canadian association of radiologists journal- journal de l association canadienne des radiologistes}, doi = {10.1177/0846537119888390}, volume = {71}, number = {1}, issn = {0846-5371}, title = {Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses}, keyword = {CT chest, CT abdomen–pelvis, multiphase scanning, radiation dose, justification}, chapternumber = {6} }
@article{article, author = {Rastogi, Shivam and Singh, Ramandeep and Borse, Riddhi and Valkovic Zujic, Petra and Segota, Doris and Diklic, Ana and Jurkovic, Slaven and Ali, Antar and Kharita, Mohammed Hassan and Al-Naemi, Huda M and Alkalbani, Jokha and Al-Rasbi, Amaal and Gershan, Vesna and Galic, Stipe and Yusuf, Mohammad and Avramova-Cholakova, Simona and Zulkipli, Ili Majidah Binti Hj and Shein, Nilar and Teferi, Seife and Rehani, Madan and Vassileva, Jenia and Kalra, Mannudeep}, year = {2020}, pages = {7}, DOI = {10.1177/0846537119888390}, chapter = {6}, keywords = {CT chest, CT abdomen–pelvis, multiphase scanning, radiation dose, justification}, journal = {Canadian association of radiologists journal- journal de l association canadienne des radiologistes}, doi = {10.1177/0846537119888390}, volume = {71}, number = {1}, issn = {0846-5371}, title = {Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses}, keyword = {CT chest, CT abdomen–pelvis, multiphase scanning, radiation dose, justification}, chapternumber = {6} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font