Pregled bibliografske jedinice broj: 1040990
Comparison of erythrocyte and leukocyte findings obtained by urine dipstick and standard microscopic sediment urinalysis with different diagnoses in dogs
Comparison of erythrocyte and leukocyte findings obtained by urine dipstick and standard microscopic sediment urinalysis with different diagnoses in dogs // 21st International Veterinary Medicine Students Scientific Research Congress
Istanbul, Turska, 2019. (poster, međunarodna recenzija, neobjavljeni rad, znanstveni)
CROSBI ID: 1040990 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of erythrocyte and leukocyte findings obtained by urine dipstick and standard microscopic sediment urinalysis with different diagnoses in dogs
Autori
Prišlin, Marina ; Posavec, Ana-Marija ; Beer Ljubić, Blanka ; Pincan, Loredana ; Šiftar, Ozren ; Vranković, Lana ; Aladrović, Jasna ; Kiš, Ivana
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, neobjavljeni rad, znanstveni
Skup
21st International Veterinary Medicine Students Scientific Research Congress
Mjesto i datum
Istanbul, Turska, 17.04.2019. - 19.04.2019
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
erythrocytes, leukocytes, dipstick, urinary sediment
Sažetak
The aim of the study was comparison of estimated erythrocyte and leukocyte count obtained by dipstick test strip with actual numbers counted in urine sediment analysis in native urine samples of dogs. Analyses of 68 native urine samples were performed in the Clinic of internal medicine. Samples were analysed by urine dipstick and standard microscopic sediment analysis. Patients were analysed as a group, and patients with problem in urinary system (N = 25) were additionally evaluated as a group. The results of dipstick analysis regarding erythrocytes were in accordance in 75%, and for the number of leukocytes in 81%. Overestimated values of erythrocytes by the dipstick were present in 25% and leukocytes in 12% of patients. There were no underestimated values for erythrocytes, while 7% of patients had lower leukocytes values. In all patients, the sensitivity of urine dipstick test for erythrocytes was 100% and for leukocytes 94% while the specificity for erythrocytes was 72% and for leukocytes 91%. The number of erythrocytes on dipstick was in congruence in 64%, and leukocytes in 44% of patients with urinary disorders compared to sediment analysis. Overestimated values of erythrocytes on the urine dipstick were recorded in 36% and in leukocytes 28% of patients. Underestimated erythrocytes values were not observed, and an underestimated value of leukocytes was found in 28% of patients.In most patients, the results of urine dipstick test analysis were in agreement with sediment analysis. Large differences between methods were observed in leukocyte count in patients with urinary tract disease and complete urinalysis in those patients is required.
Izvorni jezik
Engleski
Znanstvena područja
Veterinarska medicina
POVEZANOST RADA
Ustanove:
Veterinarski fakultet, Zagreb
Profili:
Blanka Beer Ljubić
(autor)
Marina Prišlin
(autor)
Ivana Kiš
(autor)
Lana Pađen
(autor)
Jasna Aladrović
(autor)