Naslov
Patient Maximum Skin Dose in Interventional
Radiology and Cardiology Procedures: Summary of
EURADOS Working Group 12 Activities
Autori
Ciraj-Bjelac, Olivera ; Dabin, Jeremie ; Farah, Jad ; Knežević, Željka ; Malchair, Francoise ; Siiskonen, Teemu ; on behalf of EURADOS WG12
Kolaboracija
EURADOS WG12
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, prošireni sažetak, znanstveni
Izvornik
Book of Extended Synopses, IDOS 2019
/ - Beč : International Atomic Energy Agency (IAEA), 2019, 356-357
Skup
International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS-2019)
Mjesto i datum
Beč, Austrija, 18.06.2019. - 21.06.2019
Vrsta sudjelovanja
Poster
Vrsta recenzije
Nije recenziran
Ključne riječi
Patient maximum skin dose ; interventional radiology and cardiology, EURADOS WG12
(Patient maximum skin dose ; interventional radiology and cardiology , EURADOS WG12)
Sažetak
Fluoroscopically guided interventional procedures in radiology (IR) and cardiology (IC) are techniques that have had wide diffusion in the last decades. Nevertheless, prolonged exposures due, for instance, to complicated interventional procedures or inappropriate equipment may result in high doses to both patients and staff members, in particular, with potentially high radiation doses to the skin of a patient. Evermore, as the number and complexity of interventional procedures have been steadily growing, it becomes crucial to provide patient-specific, skin dose estimate during these procedures. Working group 12 of EURADOS is dealing with various aspects of dosimetry in medical imaging. To tackle this issue, EURADOS Working group 12 has initiated a number of activities to estimate the maximum skin dose in various procedures in radiology and cardiology.This work presents Working group 12 activities in the area of dosimetry for interventional procedures in cardiology and radiology. It includes characterization of different dosimetric methods for skin dose assessment in interventional procedures, the application for skin doses measurement in clinical practice and the establishment of trigger levels.