Pregled bibliografske jedinice broj: 1028597
IONIC COMPOSITION OF PM2, 5 PARTICLE FRACTION AT A COASTAL URBAN BACKGROUND SITE IN CROATIA
IONIC COMPOSITION OF PM2, 5 PARTICLE FRACTION AT A COASTAL URBAN BACKGROUND SITE IN CROATIA // 18th World Clean Air Congress 2019 / Incecik, Selahattin ; Toros, Huseyin ; Topcu, Sema ; Ozturk, Busra ; Duzgun, Cansu ; Kursun, Ilayda (ur.).
Istanbul: TUNCAP and IUAPPA, 2019. str. 63-63 (predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 1028597 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
IONIC COMPOSITION OF PM2, 5 PARTICLE FRACTION AT A COASTAL URBAN BACKGROUND SITE IN CROATIA
Autori
Gluščić, Valentina ; Čačković, Mirjana ; Pehnec, Gordana ; Bešlić, Ivan
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
18th World Clean Air Congress 2019
/ Incecik, Selahattin ; Toros, Huseyin ; Topcu, Sema ; Ozturk, Busra ; Duzgun, Cansu ; Kursun, Ilayda - Istanbul : TUNCAP and IUAPPA, 2019, 63-63
Skup
18th World Clean Air Congress (WCAC 2019)
Mjesto i datum
Istanbul, Turska, 23.09.2019. - 27.09.2019
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
measuring site ; anions ; cations ; PCA
Sažetak
The aim of this study was to determine the mass concentration and the content of water-soluble anions (Cl-, NO3-, SO42-) and cations (Na+, NH4+, K+, Mg2+, Ca2+) in PM2.5 particle fraction, to investigate their relationship and there contribution to the total PM2.5 mass measured at site located in Rijeka, Croatia. Rijeka is the third-largest city in Croatia at Kvarner Bay on Adriatic Sea with developed petrochemical and metal industry, shipyards, oil refining and transportation especially maritime. Measuring site is a part of Croatian monitoring network for air quality classified as urban background site. Daily samples of PM2.5 particle fraction were collected over a year 2017 on PTFE filters using the low volume sampler Sven Leckel SEQ 47/50. Mass concentration of PM2.5 particle fraction was determined by gravimetric according to the standard HRN EN 12341:2014 (EN 12341:2014). The content of water-soluble inorganic anions and cations were determined using Thermo Scientific ICS-5000 capillary ion chromatograph. Results show that annual average PM2.5 mass concentration was 9.65 µg/m3 and didn't exceed limit value of 25 µg/m3 given by the Regulation on the level of pollutants in air (OG No. 117/12). The annual average mass concentrations of ions in PM2.5 particle fraction was in order SO42- > NH4+ > NO3- > Ca2+ > K+ > Na+ > Cl- > Mg2+. Contribution of total anion mass and cation mass to the total PM2, 5 mass were 25.4% and 12.8%, respectively. Contribution of each anion mass to the total anion mass were 84.8% , 14.2% and 0.9% for SO42-, NO3- and Cl- respectively, while contribution of each cation mass to the total cation mass were 6.6% , 72% , 6.2% , 1% and 13.3% for Na+, NH4+, K+, Mg2+ and Ca2+, respectively. The prediction of the pollutant sources we ran the principal component analysis (PCA) which was performed using the statistical packages STATISTICA 13.0. After varimax rotation, the obtained four principal component factors were found to account for 86% of the variance. Factor loadings > 0.7 were considered significant.