Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1026351

Construction and Validation of Protocol for Digital Measurement of Human Body


Gruić, Igor; Katović, Darko; Bušić, Anita; Bronzin, Tomislav; Medved, Vladimir; Mišigoj-Duraković, Marjeta
Construction and Validation of Protocol for Digital Measurement of Human Body // Communications in Computer and Information Science / Cabri, J. ; Pezarat-Correia, P. ; Vilas-Boas, J (ur.)., 2019. str. 86-99 doi:10.1007/978-3-030-14526-2_6


CROSBI ID: 1026351 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Construction and Validation of Protocol for Digital Measurement of Human Body

Autori
Gruić, Igor ; Katović, Darko ; Bušić, Anita ; Bronzin, Tomislav ; Medved, Vladimir ; Mišigoj-Duraković, Marjeta

Vrsta, podvrsta i kategorija rada
Poglavlja u knjigama, znanstveni

Knjiga
Communications in Computer and Information Science

Urednik/ci
Cabri, J. ; Pezarat-Correia, P. ; Vilas-Boas, J

Izdavač
Springer

Godina
2019

Raspon stranica
86-99

ISBN
978-3-030-14526-2

ISSN
1865-0929

Ključne riječi
Anthropometry ; Reliability ; Kinect ; Protocol

Sažetak
Standardized measurement protocol for assessing anthropometric dimensions of human body is precisely predefined by International Biological Programme (IBP), [16]. Objective of this research was to produce, compare, validate and standardize protocol for digital measurement (DM-I) using Kinect sensor in order to economize future large scale research. Results in selected variables revealed that classically and digitally measured parameters, e.g. height, in average results do not differ significantly, while e.g. for lengths of the left forearm and the left lower leg do indicate lower values. Different reference points used in two measurement methods, i.e. anthropometric points (IBP) and Kinect points, represent similar, but not identical representation of human body. Measures of internal consistency (reliability) for assessed digitally measured variables demonstrated high reliability, but inappropriateness for clinical trials demanding extremely high precision. Since reliability of instruments in clinical and sport application differ, broad spectrum of useful specific diagnostic tools and instruments may be produced based on results assessed in this research.

Izvorni jezik
Engleski

Znanstvena područja
Interdisciplinarne tehničke znanosti



POVEZANOST RADA


Ustanove:
Kineziološki fakultet, Zagreb,
Grafički fakultet, Zagreb,
Visoko učilište Algebra, Zagreb

Poveznice na cjeloviti tekst rada:

doi link.springer.com www.scopus.com

Citiraj ovu publikaciju:

Gruić, Igor; Katović, Darko; Bušić, Anita; Bronzin, Tomislav; Medved, Vladimir; Mišigoj-Duraković, Marjeta
Construction and Validation of Protocol for Digital Measurement of Human Body // Communications in Computer and Information Science / Cabri, J. ; Pezarat-Correia, P. ; Vilas-Boas, J (ur.)., 2019. str. 86-99 doi:10.1007/978-3-030-14526-2_6
Gruić, I., Katović, D., Bušić, A., Bronzin, T., Medved, V. & Mišigoj-Duraković, M. (2019) Construction and Validation of Protocol for Digital Measurement of Human Body. U: Cabri, J., Pezarat-Correia, P. & Vilas-Boas, J. (ur.) Communications in Computer and Information Science., Springer, str. 86-99 doi:10.1007/978-3-030-14526-2_6.
@inbook{inbook, author = {Grui\'{c}, Igor and Katovi\'{c}, Darko and Bu\v{s}i\'{c}, Anita and Bronzin, Tomislav and Medved, Vladimir and Mi\v{s}igoj-Durakovi\'{c}, Marjeta}, year = {2019}, pages = {86-99}, DOI = {10.1007/978-3-030-14526-2\_6}, keywords = {Anthropometry, Reliability, Kinect, Protocol}, doi = {10.1007/978-3-030-14526-2\_6}, isbn = {978-3-030-14526-2}, issn = {1865-0929}, title = {Construction and Validation of Protocol for Digital Measurement of Human Body}, keyword = {Anthropometry, Reliability, Kinect, Protocol}, publisher = {Springer} }
@inbook{inbook, author = {Grui\'{c}, Igor and Katovi\'{c}, Darko and Bu\v{s}i\'{c}, Anita and Bronzin, Tomislav and Medved, Vladimir and Mi\v{s}igoj-Durakovi\'{c}, Marjeta}, year = {2019}, pages = {86-99}, DOI = {10.1007/978-3-030-14526-2\_6}, keywords = {Anthropometry, Reliability, Kinect, Protocol}, doi = {10.1007/978-3-030-14526-2\_6}, isbn = {978-3-030-14526-2}, issn = {1865-0929}, title = {Construction and Validation of Protocol for Digital Measurement of Human Body}, keyword = {Anthropometry, Reliability, Kinect, Protocol}, publisher = {Springer} }

Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font