Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures


Ferrari, P.; Becker, F.; Jovanović, Zoran; Khan, S.; Bakhanova, E.; Principi, S.; Kristić, D.; Pierotti, L.; Mariotti, F.; Faj, Dario et al.
Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures // Journal of radiological protection, 39 (2019), 3; 809-824 doi:10.1088/1361-6498/ab2c42 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1019598 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures

Autori
Ferrari, P. ; Becker, F. ; Jovanović, Zoran ; Khan, S. ; Bakhanova, E. ; Principi, S. ; Kristić, D. ; Pierotti, L. ; Mariotti, F. ; Faj, Dario ; Turk, Tajana ; Nikezić, Dragan ; Bertolini, M.

Izvornik
Journal of radiological protection (0952-4746) 39 (2019), 3; 809-824

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
effective dose ; interventional radiology ; personal dosimetry ; monte carlo simulation

Sažetak
Interventional radiology and cardiology are widespread employed techniques for diagnosis and treatment of several pathologies because they avoid the majority of the side-effects associated with surgical treatments, but are known to increase the radiation exposure to patient and operators. In recent years many studies treated the exposure of the operators performing cardiological procedures. The aim of this work is to study the exposure condition of the medical staff in some selected interventional radiology procedures. The Monte Carlo simulations have been employed with anthropomorphic mathematical phantoms reproducing the irradiation scenario of the medical staff with two operators and the patient. A personal dosemeter, put on apron, was modelled for comparison with measurements performed in hospitals, done with electronic dosemeters, in a reduced number of interventional radiology practices. Within the limits associated to the use of numerical anthropomorphic models to mimic a complex interventional procedure, the personal dose equivalent, H-p(10), was evaluated and normalised to the simulated Kerma-Area Product, KAP, value, indeed the effective dose has been calculated. The H-p(10)/KAP(value) of the first operator is about 10 mu Sv/Gy.cm(2), when ceiling shielding is not used. This value is calculated on the trunk and it varies of +/-30% moving the dosemeter to the waist or to the neck. The effective dose, normalised to the KAP value, varies between 0.03 and 0.4 mu Sv/Gy.cm(2). Considering all the unavoidable approximation of this kind of investigations, the comparisons with hospital measurement and literature data showed a good agreement allowing to use of the present results for dosimetric characterisation of interventional radiology procedures.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kliničke medicinske znanosti

Napomena
This work was supported by the European Radiation Dosimetry Group (EURADOS, WG12).



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Osijek,
Medicinski fakultet, Osijek

Profili:

Avatar Url Tajana Turk (autor)

Avatar Url Dario Faj (autor)

Poveznice na cjeloviti tekst rada:

doi iopscience.iop.org

Citiraj ovu publikaciju:

Ferrari, P.; Becker, F.; Jovanović, Zoran; Khan, S.; Bakhanova, E.; Principi, S.; Kristić, D.; Pierotti, L.; Mariotti, F.; Faj, Dario et al.
Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures // Journal of radiological protection, 39 (2019), 3; 809-824 doi:10.1088/1361-6498/ab2c42 (međunarodna recenzija, članak, znanstveni)
Ferrari, P., Becker, F., Jovanović, Z., Khan, S., Bakhanova, E., Principi, S., Kristić, D., Pierotti, L., Mariotti, F. & Faj, D. (2019) Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures. Journal of radiological protection, 39 (3), 809-824 doi:10.1088/1361-6498/ab2c42.
@article{article, author = {Ferrari, P. and Becker, F. and Jovanovi\'{c}, Zoran and Khan, S. and Bakhanova, E. and Principi, S. and Kristi\'{c}, D. and Pierotti, L. and Mariotti, F. and Faj, Dario and Turk, Tajana and Nikezi\'{c}, Dragan and Bertolini, M.}, year = {2019}, pages = {809-824}, DOI = {10.1088/1361-6498/ab2c42}, keywords = {effective dose, interventional radiology, personal dosimetry, monte carlo simulation}, journal = {Journal of radiological protection}, doi = {10.1088/1361-6498/ab2c42}, volume = {39}, number = {3}, issn = {0952-4746}, title = {Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures}, keyword = {effective dose, interventional radiology, personal dosimetry, monte carlo simulation} }
@article{article, author = {Ferrari, P. and Becker, F. and Jovanovi\'{c}, Zoran and Khan, S. and Bakhanova, E. and Principi, S. and Kristi\'{c}, D. and Pierotti, L. and Mariotti, F. and Faj, Dario and Turk, Tajana and Nikezi\'{c}, Dragan and Bertolini, M.}, year = {2019}, pages = {809-824}, DOI = {10.1088/1361-6498/ab2c42}, keywords = {effective dose, interventional radiology, personal dosimetry, monte carlo simulation}, journal = {Journal of radiological protection}, doi = {10.1088/1361-6498/ab2c42}, volume = {39}, number = {3}, issn = {0952-4746}, title = {Simulation of H p (10) and effective dose received by the medical staff in interventional radiology procedures}, keyword = {effective dose, interventional radiology, personal dosimetry, monte carlo simulation} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font