Isolated vs. Interconnected Wind Turbine Grounding Systems: Effect on the Harmonic Grounding Impedance, Ground Potential Rise and Step Voltage
Isolated vs. Interconnected Wind Turbine Grounding Systems: Effect on the Harmonic Grounding Impedance, Ground Potential Rise and Step Voltage // Electric power systems research, 173 (2019), 230-239 doi:10.1016/j.epsr.2019.04.010 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1009945 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Isolated vs. Interconnected Wind Turbine Grounding Systems: Effect on the Harmonic Grounding Impedance, Ground Potential Rise and Step Voltage
Autori
Šunjerga, Antonio ; Li, Quanxin ; Poljak, Dragan ; Rubinstein, Marcos ; Rachidi, Farhad
Izvornik
Electric power systems research (0378-7796) 173
(2019);
230-239
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Grounding impedance ; Wind turbine ; Interconnected ; Ground potential rise ; Step voltage ; Frequency dependent
Sažetak
Wind turbines are very vulnerable to lightning strikes due to their height, sharp edges and remote locations often with high soil resistivity. In this paper we present numerical simulations of the impedance of a typical wind turbine grounding geometry. We analyze the influence of interconnecting grounding systems of different wind turbines. IEC TR61400-24 suggests interconnection of grounding electrodes of wind turbines through horizontal electrodes (in the form of insulated or bare conductors) to achieve low steady-state grounding resistance. The analysis takes into account the frequency dependence of the soil electrical parameters. We show that the low frequency grounding impedance can be reduced by a factor of two or more as a result of interconnecting grounding systems. However, the reduction is significantly lower at higher frequencies because of the interconnection wire’s inductance. We analyze the spatial distribution of the ground potential rise and step voltage in response to typical first and subsequent lightning return stroke current waveforms. It is shown that both, ground potential rise and step voltage can be significant along the wire, especially for high resistivity soil, and placing sensitive equipment near the interconnecting wire should be either avoided, or insulated wire should be used.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus