Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1004896

Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types


Franček, Petar; Petošić, Antonio; Budimir, Marko; Hrabar, Ivan
Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types // NDT & E international, 106 (2019), 23-41 doi:10.1016/j.ndteint.2019.05.005 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1004896 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types

Autori
Franček, Petar ; Petošić, Antonio ; Budimir, Marko ; Hrabar, Ivan

Izvornik
NDT & E international (0963-8695) 106 (2019); 23-41

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Non-destructive testing (NDT)Ultrasound transducerElectromechanical characterizationFrequency sweeping signalImpulse excitationUnloaded and loaded conditionsOptimal excitation signal typePulse width

Sažetak
This work presents an experimental method for obtaining the best excitation pulse type and width for optimal driving of an industrial non- destructive testing (NDT) ultrasound transducer by using its electrical impedance parameters as input. Within the optimization method, a classic low-voltage frequency sweeping signal and two different types of high-voltage impulse excitation signals (unipolar and bipolar), with different pulse widths, are used for the electromechanical characterization of the transducer. The optimization of the excitation signal is verified by measuring the voltage, current and electrical power of the excitation and received signals obtained by ultrasound pulse reflection from two cracks (2 mm and 3 mm) in a stainless-steel block. Additionally, the influence of the output electrical impedance of the power amplifier on the optimal transfer of electrical power from the amplifier to the loading (the NDT transducer on the block) and vice versa is also discussed in this work. The optimum working point for the ultrasound NDT transducer, regarding the impulse excitation type and its pulse width, is a bipolar impulse excitation with the width and amplitude calculated from maximum values of the measured voltage, electric current and power generated in the transducer receive mode by the reflected ultrasound signals.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
H2020-FTIPilot-2016: 760232
HRZZ-UIP-2013-11-4996 - Ultrazvučni sustav za određivanje parametara kompleksnih materijala u nelinearnim uvjetima rada (ULTRASNON) (Petošić, Antonio, HRZZ ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
INETEC

Profili:

Avatar Url Marko Budimir (autor)

Avatar Url Ivan Hrabar (autor)

Avatar Url Antonio Petošić (autor)

Avatar Url Petar Franček (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Franček, Petar; Petošić, Antonio; Budimir, Marko; Hrabar, Ivan
Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types // NDT & E international, 106 (2019), 23-41 doi:10.1016/j.ndteint.2019.05.005 (međunarodna recenzija, članak, znanstveni)
Franček, P., Petošić, A., Budimir, M. & Hrabar, I. (2019) Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types. NDT & E international, 106, 23-41 doi:10.1016/j.ndteint.2019.05.005.
@article{article, author = {Fran\v{c}ek, Petar and Peto\v{s}i\'{c}, Antonio and Budimir, Marko and Hrabar, Ivan}, year = {2019}, pages = {23-41}, DOI = {10.1016/j.ndteint.2019.05.005}, keywords = {Non-destructive testing (NDT)Ultrasound transducerElectromechanical characterizationFrequency sweeping signalImpulse excitationUnloaded and loaded conditionsOptimal excitation signal typePulse width}, journal = {NDT and E international}, doi = {10.1016/j.ndteint.2019.05.005}, volume = {106}, issn = {0963-8695}, title = {Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types}, keyword = {Non-destructive testing (NDT)Ultrasound transducerElectromechanical characterizationFrequency sweeping signalImpulse excitationUnloaded and loaded conditionsOptimal excitation signal typePulse width} }
@article{article, author = {Fran\v{c}ek, Petar and Peto\v{s}i\'{c}, Antonio and Budimir, Marko and Hrabar, Ivan}, year = {2019}, pages = {23-41}, DOI = {10.1016/j.ndteint.2019.05.005}, keywords = {Non-destructive testing (NDT)Ultrasound transducerElectromechanical characterizationFrequency sweeping signalImpulse excitationUnloaded and loaded conditionsOptimal excitation signal typePulse width}, journal = {NDT and E international}, doi = {10.1016/j.ndteint.2019.05.005}, volume = {106}, issn = {0963-8695}, title = {Electrical resonance/antiresonance characterization of NDT transducer and possible optimization of impulse excitation signals width and their types}, keyword = {Non-destructive testing (NDT)Ultrasound transducerElectromechanical characterizationFrequency sweeping signalImpulse excitationUnloaded and loaded conditionsOptimal excitation signal typePulse width} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font