The Possibility of Improving Mineral Water Quality Using Selective Ion Exchange Column (CROSBI ID 63905)

Prilog u knjizi | izvorni znanstveni rad | međunarodna recenzija

Cvrk, Ramzija ; Softić, Mirza ; Begić, Sabina ; Habuda Stanić, Mirna The Possibility of Improving Mineral Water Quality Using Selective Ion Exchange Column // New Technologies, Development and Application II / Karabegović, Isak (ur.). Cham: Springer, 2019. str. 576-580 doi: 10.1007/978-3-030-18072-0_66

Podaci o odgovornosti

Cvrk, Ramzija ; Softić, Mirza ; Begić, Sabina ; Habuda Stanić, Mirna

engleski

The Possibility of Improving Mineral Water Quality Using Selective Ion Exchange Column

The quality of mineral water is conditioned by a number of factors, primarily the quality of water in the water source. The aim of this study was to determinate content of Ni2+ and Mn2+ ions in the mineral water, after treatment by selective ion- exchange column. The primary objective of investigated technological process was optimal performance of the column, during the processing of water, so that the content of Ni2+ and Mn2+ ions in the mineral water, after treatment reduce to allowable concentration, and the concentration of Mg2+ ions in the mineral water decreases insignificantly, and thereby the cost of water treatment are not increased. Also, during the study, was determined the effect of application of ion - exchange columns in the physico-chemical water parameters, such as turbidity of the water, the water hardness and pH value. The results showed a statistically significant difference (p < 0, 01) in the content of Ni2+ and Mn2+ ions before, and after treatment, so that the mean concentration of nickel in water before processing is 0, 187359 mg/l, and after the treatment, this value is 0, 015600 mg/l. For the Mn2+ ion concentration value before processing is 0, 113294 mg/l and after treatment this value was 0, 008206 mg/l. It should be noted that changes in the concentration of Mg2+ ions there is no statistical significance, before treatment was 388, 59 mg/l, and after treatment 383, 80 mg/l.

quality of mineral water, selective ion-exchange column

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

576-580.

objavljeno

10.1007/978-3-030-18072-0_66

Podaci o knjizi

New Technologies, Development and Application II

Karabegović, Isak

Cham: Springer

2019.

978-3-030-18071-3

Povezanost rada

Kemijsko inženjerstvo, Prehrambena tehnologija

Poveznice