Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Comparison of two serum collection tubes for insulin determination (CROSBI ID 675464)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Grdiša, Katarina ; Radišić Biljak, Vanja ; Božičević, Sandra ; Krhač, Maja ; Vučić Lovrenčić, Marijana Comparison of two serum collection tubes for insulin determination / Plebani, Mario (ur.). Berlin: Walter de Gruyter, 2017. str. eA15-eA15 doi: 10.1515/cclm-2017-0137

Podaci o odgovornosti

Grdiša, Katarina ; Radišić Biljak, Vanja ; Božičević, Sandra ; Krhač, Maja ; Vučić Lovrenčić, Marijana

engleski

Comparison of two serum collection tubes for insulin determination

BACKGROUND-AIM: The accuracy of serum insulin determination is dependent on preanalytical conditions, affecting the stability of the peptide structure. Becton Dickinson (BD) Vacutainer clot activator serum tube (CAT) and the serum separator tube (SST II advance) are commonly and often interchangeably used serum collection tubes. Our aim was to compare insulin concentration in sera collected in BD CAT and SST tubes and evaluate the equivalence of results for the clinical use. METHODS: Venous blood from 45 fasting subjects with impaired glucose tolerance and type 2 diabetes mellitus was collected using both BD CAT and SST tubes in sequence. Sera from both tubes, obtained after clotting and centrifugation (10 min, 3000xg) were assayed for insulin with an automated chemiluminescent immunoassay (Centaur XP, Siemens Diagnostic Solutions, USA). The results were analyzed using MedCalc statistical software. RESULTS: Serum insulin levels ranged from 25, 6 to 346, 0 pmol/L. Passing & Bablok regression analysis revealed no statistically significant systematic or proportional differences between the two compared collection tubes (regression equation: y = -0, 659867 + 1, 009806 x ; Intercept A = -0, 6599, 95% CI = -4, 3740 to 4, 2282 ; Slope B = 1, 0098, 95% CI = 0, 9673 to 1, 0479). Cusum test for linearity showed no significant deviation from linearity (P = 0, 59). CONCLUSION: The result from this study support the use of both serum collection tubes for insulin concentration determination as they give clinically equivalent results.

insulin, serum tubes, comparison

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

eA15-eA15.

2017.

objavljeno

10.1515/cclm-2017-0137

Podaci o matičnoj publikaciji

Plebani, Mario

Berlin: Walter de Gruyter

1434-6621

1437-4331

Podaci o skupu

4th EFLM-BD European Conference on Preanalytical Phase

poster

24.03.2017-25.03.2017

Amsterdam, Nizozemska

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost