Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Diagnostic Accuracy Of Siemens Advia 2120i Hematology Analyzer İn Detecting Pseudothrombocytopenia (CROSBI ID 675374)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Bogić, Anamarija ; Vuljanić, Dora ; Petro, Dubravka ; Radišić Biljak, Vanja ; Šimundić, Ana-Maria Diagnostic Accuracy Of Siemens Advia 2120i Hematology Analyzer İn Detecting Pseudothrombocytopenia / Plebani, Mario (ur.). Berlin: Walter de Gruyter, 2018. str. eA299-eA299

Podaci o odgovornosti

Bogić, Anamarija ; Vuljanić, Dora ; Petro, Dubravka ; Radišić Biljak, Vanja ; Šimundić, Ana-Maria

engleski

Diagnostic Accuracy Of Siemens Advia 2120i Hematology Analyzer İn Detecting Pseudothrombocytopenia

Aim: The aim of the study was to investigate the diagnostic accuracy of Siemens Advia 2120i hematology analyzer in detection of pseudothrombocytopenia. Materials and methods: Total of 160 K2EDTA whole blood samples (platelet count <100x109/L) were included. All samples were inspected for presence of platelet clumps in peripheral blood smears (stained with May-Grünwald Giemsa) with manual microscopy using Motic BA410, as a reference method. The presence of the two categories of flags (platelet clumps and large platelets) were recorded. Specificity and sensitivity for each flag category, as well as for their combination, were calculated. Criteria for sensitivity and specificity (2016 state-of-the-art by Vis and Huisman) were >80% and >98%, respectively. Results: Platelet clumps were confirmed in 10/160 and large platelets in 9/160 samples. Specificity of Advia 2120i in detecting platelet clumps was excellent (>99%), while sensitivity was poor (36%). The sensitivity and specificity of Advia 2120i in detecting large platelets were satisfactory (82% and 88%, respectively). Combining both flags as an alert for peripheral blood smear review, improved the diagnostic accuracy of detecting platelet clumps in patients samples (specificity 99%, sensitivity 83%) as some of the truly positive samples had overlaps between clumps and large platelets. Conclusions: Siemens Advia 2120i hematology analyzer has acceptable accuracy in detection of pseudothrombocytopenia, with a false negative rate of 16.7% (2/12 samples). Based on these results, our laboratory protocol is to perform microscopic examination of all samples with platelets count <100x109/L if either of the morphology flags (platelet clumps and large platelets) is reported by the analyser.

hematology analyser, pseudothrombocytopenia, flagging efficiency

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

eA299-eA299.

2018.

objavljeno

Podaci o matičnoj publikaciji

Plebani, Mario

Berlin: Walter de Gruyter

1434-6621

1437-4331

Podaci o skupu

5th EFLM-UEMS European Joint Congress in Laboratory Medicine

poster

10.10.2018-13.10.2018

Antalya, Turska

Povezanost rada

nije evidentirano

Indeksiranost