Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Cryoablation decreases platelet reactivity in patients with atrial fibrillation compared with radiofrequency ablation: results from the Sparelife Project (CROSBI ID 674969)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Samardžić, Jure ; Velagić, Vedran ; Skorić, Boško ; Pavasović, Saša ; Pašalić, Marijan ; Jurin, Hrvoje ; Planinc, Ivo ; Čikeš, Maja ; Puljević, Davor ; Miličić, Davor Cryoablation decreases platelet reactivity in patients with atrial fibrillation compared with radiofrequency ablation: results from the Sparelife Project. 2017. str. 375-375 doi: 10.15836/ccar2017.375

Podaci o odgovornosti

Samardžić, Jure ; Velagić, Vedran ; Skorić, Boško ; Pavasović, Saša ; Pašalić, Marijan ; Jurin, Hrvoje ; Planinc, Ivo ; Čikeš, Maja ; Puljević, Davor ; Miličić, Davor

engleski

Cryoablation decreases platelet reactivity in patients with atrial fibrillation compared with radiofrequency ablation: results from the Sparelife Project

Introduction: Pulmonary vein isolation (PVI) procedures increase the potential thromboembolic risk.1The aim of this study was to compare the effect of radiofrequency (RF) ablation and cryoablation on platelet reactivity (PR) in patients with atrial fibrillation (AF). Patients and Methods: We analyzed PR levels using Multiplate function analyzer in 63 consecutive pa-tients undergoing PVI procedures in our institution. Blood samples were drawn just before the proce-dure and on the following day. Fourty six (46) and seventeen (17) patients underwent cryoablation and RF ablation, respectively. There was no difference in demographics and baseline platelet parameters (platelet count, MPV and PR) between patients in RF and cryo group. ASPI, ADP and TRAPtest were used to --assess multiple pathways of platelet activation. Results: One day after the procedure mean PR droped from baseline levels in both study groups. The observed delta was more expressed in the cryo group for all three PR tests but only ADPtest showed statistically significant difference in PR. Conclusion: Our results show that PR after cryoablation is less pronounced compared to RF procedure. This affirms that thrombogenic burden of PVI is lower with cryoablation. We hypothesize that this could be a result of endocardial integrity preservation and decreased availability of platelet agonists during cryoablation. These results warrant further investigations with periinterventional PR meas-urements on a larger cohort of patients

atrial fibrillation, pulmonary vein isolation, platelet reactivity

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

375-375.

2017.

objavljeno

10.15836/ccar2017.375

Podaci o matičnoj publikaciji

1848-543X

Podaci o skupu

5th Cardiology Highlights − the ESC Update Meeting

poster

19.10.2017-22.10.2017

Dubrovnik, Hrvatska

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost